The TM100 is configured ex works ie. no adjustments

are neccessary. To adapt for other applications (ie.

different sensor) you can adjust by changing the

configuration.

Press and hold key (9) for 4 seconds to enter

configuration while TM100 is on (display shows

“SET”). Select key (4) or (5) depending which input

you want to configure, applies also to TM100 with

one input only. Now you can modify the 6 input

parameters (+ 3 mode dependant parameters). Please

find parameter details in the table below.

Choose the parameter using keys (4) and (5). The

display changes to parameter-no. (“P x” while x stands

for the parameter number).

Use keys (6) and (7) to adjust the selected parameter.

To choose another parameter use keys (4) or (5) again.

To save changes press and hold key (9) until display

reads “SET”.

To cancel changes press and hold key (8) until display

reads “CAn” (Cancel).

6

Configuration

inst

inst

(9)

A

A

(4)

B

B

(5)

or

A

A

(4)

B

B

(5)

previous / next parameter

max

max

-

-

(6)

grad

grad

+

+

(7)

decrease (-) resp. increase (+) value

on

on
off

off

(8)

hold = cancel

inst

inst

(9)

hold = save + quit

Parameter List

No. Description

Range

Default

Unit

1

input mode

0 - 4

-

0 = input unused

2

value averaging

1 - 5

4

-

3

fullscale trim

-10.0 - 10.0

0.0

percent (%)

4

zero offset

+/-100

0

same like value

5

sensitivity J/K thermocouple

1, 2

1

-

6

decimals

0 - 3

0

-

7 to  9  input mode dependant (see following page)

long

Содержание TM 100

Страница 1: ...TM 100 Operating Instructions Thermocomputer TM100 B A max grad on off inst charging B A ...

Страница 2: ...ow 11 Charging socket rechargable option only Introduction 1 Safety Notes 1 Setup 1 Displaying Temperatures 2 Maximum Values 2 Absolute Maximums 2 Temperature Gradient 2 Cold Junction Temp Battery Voltage 3 TM100 O2 3 Changing Combustion Composites 4 Charging 4 Replacing Batteries 4 Opening TM100 4 Messages Display Codes 5 Error Messages 5 Configuration 6 Parameterlist 6 Technical Data 7 3 4 6 8 1...

Страница 3: ...d this booklet carefully to become familiar with the various features and options of your new instrument Only connect the proper type of thermocouple to the TM100 to avoid damage of kiln and load due to wrong temperature indication When receiving TM100 and sensor as a package it is configured properly Never put your TM100 on top of a kiln Carefully insert the thermocouple plug into the socket 1 TM...

Страница 4: ...ed when replacing batteries There it is an valuable indication in case of warranty disputes damage of kiln bricks etc The current increase of temperature gradient is a value of interest especially when firing gas kilns manually The value is shown in centigrade Celsius per hour positive on increasing temperatures or negative when kiln temperature drops Sudden changes in temperatures very large or v...

Страница 5: ... uses a highly complex combustion formula to calculate all relevant atmosphere parameters oxygen O2 carbon monoxide CO carbon dioxide CO2 air gas ratio lambda To enable the TM100 this calculation some parameters of the combustable need to be entered in the configuration menue The temperature signal of the probe is connected to input A the O2 signal is lead to input B Due to physical laws an oxygen...

Страница 6: ...ks The LED goes off of the battery is fully charged New NiMh type rechargable batteries achieve their maximum capacity lasts for a couple of month s operation after the 3rd loading cycle Depending on usage the supplied batteries last up for years Use size AA Mignon batteries only Replace batteries once the experation date is elapsed although they provide power to avoid chemicals to poor out Carefu...

Страница 7: ...em inside the TM100 Contact us for assistance Error C1 internal check failed no further data acquisition Points to an internal problem of the signal converter Error C2 internal check found values to be inaccurate Might be caused by exceeding temperature range when water entered or electronic damage Error D1 hardware damage Contact us for repair Error D5 TM100 calibration data invalid loss of calib...

Страница 8: ...er no P x while x stands for the parameter number Use keys 6 and 7 to adjust the selected parameter To choose another parameter use keys 4 or 5 again To save changes press and hold key 9 until display reads SET To cancel changes press and hold key 8 until display reads CAn Cancel 6 Configuration inst inst 9 A A 4 B B 5 or A A 4 B B 5 previous next parameter max max 6 grad grad 7 decrease resp incr...

Страница 9: ... 0 c 2007 bentrup Industriesteuerungen D 35463 Fernwald Accuracy 0 1 refered to full scale Operating temperature range 15 to 55 C Storage temperature range 25 to 85 C Batterie lifetime about 2 years Alkaline Batterie lifetime rechargable about 6 months NiMh Loading time about 6 hours Maximum loading cycles 100 Charging power supply 9V AC 500mA Technical Data No Description Range Default Unit 7 Car...

Отзывы: