33
Bentone BF1
General
8.1.3 Technical data
LMO14
LMO24
Pre-ignition period:
15 s
25 s
Pre-ventilation period:
16 s
26 s
Post-ignition period:
10 s
5 s
Safety period:
< 10 s
< 5 s
Re-connection after release:
< 1 s
< 1 s
Reaction time lame extinction:
< 1 s
< 1 s
Ambient temperature:
-5 - +60°C
-5 - +60°C
Min. current with lame:
45 µA
45 µA
Max current when dark, start:
5,5 µA
5,5 µ A
Ingress Protection:
IP 40
IP 40
LOA not to be used within EU
Photocell current checks
Photocell current is measured with a direct current ammeter
(mulitimeter μA) connected in series with the photocell.
Содержание BF1 RME
Страница 2: ......
Страница 11: ...11 Bentone BF1 General 2 11 12 1 10 5 15 24 22 21 23 13 3 17 14 19 20...
Страница 36: ...10 DECLARATION OF CONFORMITY...
Страница 38: ......
Страница 39: ......
Страница 40: ...Enertech AB P O Box 309 SE 341 26 Ljungby www bentone se www bentone com...