14
Bentone BF1
General
4. BASIC SETTINGS
4.1 Example of basic setting
4.1.1 Choice of nozzle
BF1 FU 63-16/BF1 K 76-26
Burner output
30 kW
Estimated nozzle output:
30 / 11,86*
=
2,53 kg/h
Choice of nozzle according to table. (Refer to Technical data.)
According to the nozzle table, the following nozzle is indicated:
Nozzle:
0,65 Gph
Pump pressure:
11,0 bar
BF1 FUV 63-16/BF1 KV 76-26
Burner output
30 kW
Because of preheater, output is adjusted upward for choice of nozzle
according to table. (Refer to Technical data 2.6).)
Estimated nozzle output:
30 x 1,06
=
31,8 kW
31,8 / 11,86*
=
2,68 kg/h
Choice of nozzle according to table. (Refer to Technical data).
According to the nozzle table, the following nozzle is indicate
Nozzle:
0,75 Gph
Pump pressure:
9,5 bar
* Caloric value Light oil
=
11,86 kWh/kg
4.1.2 Basic setting
Setting values for 30 kW according to basic settings tables.
(Refer to Technical data FUV 63-16).
Air setting
=
11,0
Insert setting
=
4,0
Содержание BF1 RME