12
Bentone BF1
General
3. INSTALLATION
3.1 Delivery checks
Check that everything has been delivered and that the goods are not
transport damaged. Any delivery faults must be reported to the supplier.
Transport damage must be reported to the forwarder.
3.2 Preparations for installation
Check that the burner’s measurements and capacity range is suitable for
the boiler in question. The power information on the data plate refers to the
burner’s max. and min. power.
3.3 Oil supply
In order to achieve good operational reliability it is important that the oil
supply system is laid out correctly.
Observe the following:
• Choice of pipe diameters, pipe lengths and height differences (refer to
pump instructions).
• Piping should be run with a minimum of joints/compression ittings.
• Pipework must be laid out so that oil hoses are not subjected to
tension or overbending when the burner is swung out or removed for
service.
• The oil ilter should be installed so that the ilter cartridge can easily be
replaced
3.4 Electrical connection
Before electrical installation is begun, electricity must be switched off at
the main switch. If the boiler has a 7-pole or a 4-pole Eurostecker (only on
2-stage burners), these often it directly to the burner. Otherwise use the
connectors supplied. The operating thermostat, the max. thermostat and the
inspection hatch (where itted) interlock can then be wired in series on the
incoming phase connected to L1 or connected between T1 and T2. In the
irst mentioned case a jumper is installed between T1 and T2.
(Refer to connection in the section Electrical equipment).
3.5 Choice of nozzle
(Technical data): Recommended nozzle and nozzle table.
3.6 Brake plate and airflow setting
Before operations basic burner setting may be made according to the
diagram. (Refer to basic settings). Note that this only refers to the basic
setting; the setting must be adjusted after the burner has been started.
At this time lue gas analysis and soot measurement must be carried out.
!
If any electrical connection is used other than that recommended
by Enertech, there may be a risk of equipment damage and personal injury.