background image

171 505 44  07-01

   

Gph

8

9

10

11

kg/h kW Mcal/h kg/h kW Mcal/h kg/h kW Mcal/h kg/h kW Mcal/h

0,40

1,33

16

13

1,41

17

14

1,49

18

15

1,56

18

16

0,50

1,66

20

17

1,76

21

18

1,86

22

19

1,95

23

20

0,60

2,00

24

20

2,12

25

22

2,23

26

23

2,34

28

24

0,65

2,16

26

22

2,29

27

23

2,42

29

25

2,54

30

26

0,75

2,49

29

25

2,65

31

27

2,79

33

28

2,93

35

30

0,85

2,83

33

29

3,00

36

31

3,16

37

32

3,32

39

34

1,00

3,33

39

34

3,53

42

36

3,72

44

38

3,90

46

40

1,10

3,66

43

37

3,88

46

39

4,09

48

42

4,29

51

44

1,20

3,99

47

41

4,24

50

43

4,47

53

46

4,68

55

48

1,25

4,16

49

42

4,40

52

45

4,65

55

47

4,88

58

50

1,35

4,49

53

46

4,76

56

48

5,02

59

51

5,27

62

54

1,50

4,98

59

51

5,29

63

54

5,58

66

57

5,85

69

60

1,65

5,49

65

56

5,82

69

59

6,14

73

63

6,44

76

66

1,75

5,82

69

59

6,18

73

63

6,51

77

66

6,83

81

70

2,00

6,65

79

68

7,06

84

72

7,45

88

76

7,81

93

80

2,25

7,49

89

76

7,94

94

81

8,38

99

85

8,78

104

89

2,50

8,32

99

85

8,82

105

90

9,31

110

95

9,76

116

99

2,75

9,15

108

93

9,71

115

99

10,24

121

104

10,73

127

109

3,00

9,98

118

102

10,59

126

108

11,16

132

114

11,71

139

119

3,50

11,65

138

119

12,35

146

126

13,03

154

133

13,66

162

139

4,00

13,31

158

136

14,12

167

144

14,89

176

152

15,62

185

159

4,50

14,97

177

153

15,88

188

162

16,75

198

171

17,57

208

179

5,00

16,64

197

170

17,65

209

180

18,62

221

190

19,52

231

199

5,50

18,30

217

187

19,42

230

198

20,48

243

209

21,47

255

219

6,00

19,97

237

204

21,18

251

216

22,34

265

228

23,42

278

239

6,50

21,63

256

220

22,94

272

234

24,20

287

247

25,37

301

259

7,00

23,29

276

237

24,71

293

252

26,06

309

266

27,33

324

279

7,50

24,96

296

254

26,47

314

270

27,92

331

285

29,28

347

298

8,00

26,62

316

271

28,24

335

288

29,79

353

304

31,23

370

318

8,50

28,28

335

288

30,00

356

306

31,65

375

323

33,18

393

338

9,00

29,95

355

305

31,77

377

324

33,59

398

342

35,14

417

358

NOZZLE TABLE

Pump pressure bar

The table applies to oil with a viscosity of 4,4 mm

2

/s (cSt) with density 830 kg/m

3

.

Burner with preheater

Consider that on preheating the oil quantity is reduced by 5-20% depending on.

-  Rise in temperature at the nozzle

-  Design of nozzle

-  Capacity (high capacity - small difference)

1(2)

Содержание B30A2.2H

Страница 1: ...Providing sustainable energy solutions worldwide 178 066 52 1 2016 04 18 Installation and maintenance instruction B30A2 2H B30A2 2HL...

Страница 2: ......

Страница 3: ...Cover inspection glass 10 Switch I II 11 Switch I 0 12 Fan wheel 13 Motor 14 Nozzle assembly adjustment 15 Blast tube 16 Photo cell 17 Adjustment device 18 Indication air damper 19 Connecting pipe St...

Страница 4: ...range and nozzles recommended The net calori c value of 11 86 kWh kg for light oil has been used 188 415 B 372 108 108 220 303 281 160 190 108 35 Recommended nozzle Because of different boiler types e...

Страница 5: ...e an optimum adjust ment is obtained If larger nozzles are used the preadjustment of both the air volume and the nozzle assembly must be increased A whistling sound may be heard which can be eliminate...

Страница 6: ...e an optimum adjust ment is obtained If larger nozzles are used the preadjustment of both the air volume and the nozzle assembly must be increased A whistling sound may be heard which can be eliminate...

Страница 7: ...ge Set the operating switch S2 on low capacity I Loosen the screw A and turn the damper to the position wan ted Tighten the screw A again Second stage Set the operating switch S2 on high capacity II S...

Страница 8: ...at the main switch and cut off the oil supply Open the cover and disconnect the connecting pipes by loosening screw A and nut B Service of burner head 171 305 47 09 01 1 Loosen or swing out the burne...

Страница 9: ...l burner control LMO24 255 Wiring diagram ELECTRIC EQUIPMENT 1 3 1N 50 60 Hz 230 V If the boiler is not equipped with wired contacts connect the enclosed contacts to terminals X4 and X6 in accordance...

Страница 10: ...on till the prepurge period expires and the solenoid valve 1 opens 2 2 Solenoid valve 1 opens Oil mist is formed and ignited The photocell indicates a ame 3 The safety time expires a If no ame is est...

Страница 11: ...the problem by pressing and holding the reset button for 3 seconds The number of ashes below is repeated with a pause in between 2 ashes No ame signal when safety time expires 4 ashes False light dur...

Страница 12: ...length in metres at a nozzle capacity of 9 5 Gph Max permissible pres sure at the suction and pressure side is 2 0 bar Components 1 Nozzle outlet G 1 8 Stage 2 2 Pressure gauge port G 1 8 3 Nozzle out...

Страница 13: ...it is assured by a bleed at on the piston In one pipe operation a high pressure connection must be loosened until the air is evacuated from the system Cut Off The solenoid valves of the A2L pump are o...

Страница 14: ...93 9 71 115 99 10 24 121 104 10 73 127 109 3 00 9 98 118 102 10 59 126 108 11 16 132 114 11 71 139 119 3 50 11 65 138 119 12 35 146 126 13 03 154 133 13 66 162 139 4 00 13 31 158 136 14 12 167 144 14...

Страница 15: ...1 21 133 114 11 67 138 119 12 11 144 123 12 53 148 128 3 00 12 23 145 125 12 73 151 130 13 21 157 135 13 67 162 139 3 50 14 27 169 145 14 85 176 151 15 42 183 157 15 95 189 163 4 00 16 31 193 166 16 9...

Страница 16: ...of magnetic valve Burner fails to start Lamp not lit Motor runs Burner runs to lockout Fuse has blown Appliance thermostat has not reset Appliance overheat device has operated Control relay or photoce...

Страница 17: ...sont conformes aux normes et aux documents normatifs suivants et satisfont aux crit res applicables des directives CE suivantes Dokument EN 267 EN 60335 EU direktiv EU Directives EU Direktiven CE suiv...

Страница 18: ...he burner will not start Press the reset button on the relay Check that the thermostats are correctly adjusted Don t forget the room thermostat check that any fusesare intact and main switch is on If...

Страница 19: ......

Страница 20: ...Enertech AB P O Box 309 SE 341 26 Ljungby www bentone se www bentone com...

Отзывы: