Section 2 - INSTALLATION
7
LVDT MOUNTING
Generally, configurations for the LVDT installations will vary; however, for all
installations, brackets or other structural members used to mount the LVDT
assembly must be rigid. If the bracket is flexible, undesireable relative motion
between the LVDT and observed machine part may result. Brackets must support
the LVDT so that the core axis aligns with the movement of connecting linkage.
Assembly installation is as follows.
a. Mount the LVDT housing to the designated mounting location. (Refer to
Figures A-2, A-3, and A-4, outline of LVDT housing assemblies, for
dimensions and component locations.) Housing mounting holes are
determined by the user.
b. Attach the connecting linkage between the machine and LVDT plunger.
Assure that linkage supports are properly aligned, linkage is free from
binding, and travel is unobstructed throughout the measurement range.
c. Check that the LVDT/housing assembly components are secure and housing
is free of foreign material. Final adjustment is performed after completing
electrical installation.
CAUTION
TO PREVENT LOSS OF MACHINE
PROTECTION, SECURE THE PUSH ROD
AND THE CORE PIN USING GLUE.
RECOMMENDED, LOCTITE
THREADLOCKER 242 (BNC PART NO,
04576130).