background image

Section 2 -  INSTALLATION 

 

5

2. INSTALLATION 

RECEIVING INSPECTION 

Visually inspect exterior and interior to determine if any shipping damage has 
occurred. (Figures A-2, A-3, and A-4 illustrate the fasteners that retain the housing 
cover.) 

If shipping damage is apparent, file a claim with the carrier and submit a copy to 
BNC. The transducer housing assembly model number and appropriate option 
numbers listed in Table 1-1 should be included with all correspondence. The user 
will be advised concerning repair or replacement in accordance with the 
guarantee. 

OPERATING DIRECTION 

Correct function of the LVDT instrument system requires that the transducer be 
properly oriented to the measured machine movement according to the direction 
option of the instrument; Toward-LVDT or Away-From-LVDT. 

The direction option specifies the direction of LVDT core motion that produces 
upscale meter movement at the instrument. Refer to the Option Table of the 
instrument manual for the direction option. Figure 1-2 defines the toward-LVDT 
direction; away-from-LVDT is opposite. Regardless of the instrument direction 
option, core motion toward the LVDT produces a positive-going transducer 

output signal. 

Содержание 19045

Страница 1: ...Part Number TW8029303 Rev D 08 07 Bently Nevada Asset Condition Monitoring Installation Manual DC LVDT Housing Assembly Model 19045 19046 19047...

Страница 2: ...is document is subject to change without notice Contact Information The following ways of contacting Bently Nevada are provided for those times when you cannot contact your local representative Mailin...

Страница 3: ...t the end of its use are solely responsible for the proper disposal of the product No person firm corporation association or agency that is in control of product shall dispose of it in a manner that i...

Страница 4: ...DC LVDT Housing Assembly Model 19045 19046 19047 Installation Manual iv Contents 1 DESCRIPTION 1 2 INSTALLATION 5 3 MAINTENANCE 11 4 RECOMMENDED SPARE PARTS 12 5 APPENDIX SPECIFICATIONS 13...

Страница 5: ...a machine case as operating conditions vary The LVDT is connected mechanically between a reference point on the machine foundation and a point on the machine that exhibits the measured expansion Inpu...

Страница 6: ...6 AXX 01 DC LVDT Housing Assembly with Model 2000 HR DC LVDT 02 DC LVDT Housing Assembly with Model 2000 HR DC LVDT 19047 AXX 01 DC LVDT Housing Assembly with Model 2000 HR DC LVDT 9 25 in span max 02...

Страница 7: ...t of phase that are coupled to the primary by the movable core Core position determines the output voltage amplitude of each secondary The secondary outputs are applied to a demodulator which produces...

Страница 8: ...DC LVDT Housing Assembly Model 19045 19046 19047 Installation Manual 4 Figure 1 2 DC LVDT Output versus Core Position...

Страница 9: ...ning repair or replacement in accordance with the guarantee OPERATING DIRECTION Correct function of the LVDT instrument system requires that the transducer be properly oriented to the measured machine...

Страница 10: ...general linkage design should conform to the following guidelines 1 Linkage must not bind throughout the travel range 2 Linkage weight must not be borne by the LVDT 3 Adjustment provision is required...

Страница 11: ...unting location Refer to Figures A 2 A 3 and A 4 outline of LVDT housing assemblies for dimensions and component locations Housing mounting holes are determined by the user b Attach the connecting lin...

Страница 12: ...ve voltage conductors do not become cross wired An OK indication may be obtained but the equipment will not be operational Prolonged cross wired connection can change the output stage characteristics...

Страница 13: ...ls at the terminal block c Connect the DMM to SIG and COM at the terminal block d Manually adjust core position until the DMM displays 0 00 Vdc e Move the LVDT core as follows If full scale expansion...

Страница 14: ...Installation Equipment RECOMMENDED EQUIPMENT EQUIPMENT SPECIFICATIONS Hewlett Packard HP970A 3 1 2 digit display with Digital Multimeter DMM 0 to 1000 Vdc 0 to 1000 Vac 0 to 1000 mA dc 0 to 1000 mA a...

Страница 15: ...he Specifications and related drawings for necessary dimensions c Connect the DMM to the LVDT SIG and COM terminals The voltage should measure 0 Vdc 0 5 volt d Measure the LVDT outputs with the core p...

Страница 16: ...ntenance are listed below If the instrument system is located in a remote area or is used on an extremely critical application several spares may be desired To order replacement units specify the comp...

Страница 17: ...to 71 C Storage 54 C to 93 C Shock 250 g for 11 ms Vibration 10 g 0 to 2 kHz Construction Body Series 400 magnetic stainless steel Coil Laminated glass epoxy Lead Wire 24 gage stranded copper Teflon i...

Страница 18: ...ohm 200 k ohm Physical See Figure A l Body Length A 6 75 171 8 1 206 11 5 292 Body Diameter B 0 812 20 6 Body End to NuU Center C 2 73 69 3 3 41 86 6 4 99 126 7 Core Length D 3 15 80 4 25 108 5 30 135...

Страница 19: ...Section 5 APPENDIX SPECIFICATIONS 15 Figure A l DC LVDT Dimension Identification...

Страница 20: ...DC LVDT Housing Assembly Model 19045 19046 19047 Installation Manual 16...

Страница 21: ...Section 5 APPENDIX SPECIFICATIONS 17...

Страница 22: ...DC LVDT Housing Assembly Model 19045 19046 19047 Installation Manual 18...

Отзывы: