ENGLISH
INTRODUCTION
The ECLIPSE2 is an electronic key reader without electrical contacts. The reader is
designed to be fitted recessed into the boxes used for domestic switches and sockets.
TECHNICAL SPECIFICATIONS
System Compatibility:
Absoluta, Kyo, Norma8/4 and NORMA series panels
Current Draw:
30 mA
Frequency band:
125 KHz
Magnetic field strength:
65.8 dB
A/m
Dimensions (WxHxD):
19 x 35 x 44 mm
Environment:
Indoor Application only (outside in a watertight container)
IDENTIFICATION OF PARTS
The numbers in boldface (in square brackets
[ ]
) in this manual refer to the parts
shows in Fig. 1 and described below.
1
Red LED - All-Reader-Partitions Arming Mode
2
Yellow LED -
A
Arming Mode.
3
Green LED -
B
Arming Mode.
4
Sensitive field.
5
Dip-switches for programming the reader.
6
Connection terminal board.
7
ECL2-UKR - Universal Reader Module: terminal side.
8
Cover for ECL2-UKR Universal Reader Module.
9
MINIPROXI.
10
SAT2 key.
11
PROXI-CARD.
12
ECL2-UKR - Universal Reader Module: label side.
TERMINALS
This paragraph provides a summary of the terminals for connecting the ECLIPSE2
reader to the terminals on the control panel (see table below).
Terminals
DESCRIPTION
v (V)
I (A)
+
Power supply:
positive
11.0 - 13.8
0.03
C
Command
–
–
R
Response
–
–
–
Power supply:
negative
0
–
The BPI level of the reader is 12 V and is NOT modifiable.
ECLIPSE2 Readers must be located at least 10 cm apart.
OPERATING PRINCIPLES
The ECLIPSE2 reader is compatible with all BENTEL control panels of last generation:
if the reader is being used with panels in the
NORMA8/NORMA4
series, set
microswitch
6
on dip-switch [
5
] to the
ON
position (the default setting is OFF).
Set microswitch 6 before supplying power to the ECLIPSE2 reader.
Microswitches 1, 2, 3, 4 and 5 on dip-switch [
5
] are used for programming the
address of the device (see table 1).
Bringing the electronic key into proximity with the sensitive area [
4
] of an ECLIPSE2
makes it possible to switch the system OFF or ON.
Procedures for switching the system OFF and ON using the ECLIPSE2 reader are
different depending on the type of control panel fitted.
For more information see table below:
WARNING - Do NOT connect the ECLIPSE2 to the bus when the bus is live; if this is not possible, connect the bus terninals in the following order: -; +; R, C.
Recycling information
BENTEL SECURITY recommends that customers dispose of their used equipments
(panels, detectors, sirens, and other devices) in an environmentally sound manner.
Potential methods include reuse of parts or whole products and recycling of
products, components, and/or materials. For specific information see:
http://www.bentelsecurity.com/index.php?o=environmental
Waste Electrical and Electronic Equipment (WEEE) Directive
In the European Union, this label indicates that this product should
NOT be disposed of with household waste. It should be deposited
at an appropriate facility to enable recoveryand recycling. For
specific information see:
http://www.bentelsecurity.com/index.php?o=environmental
Hereby, Bentel Security declares that the radio equipment type
ECLIPSE2
is in compliance with Directive 2014/53/EU.
The full text of the EU declaration of conformity is available at the following internet address: www.bentelsecurity.com/dc.
BENTEL SECURITY srl reserves the right to modify the technical specifications of this product without prior notice.
Fig. 1
- Parti - Parts
Partes - Composants
OPERATIONS
Microswit-
ch No. 6
CONTROL
PANELS
PROCEDURE
LEDs
Red Yellow Green
Disarm
OFF
ABSOLUTA, KYO320,
KYOUNIT, NORMA
1.
Hold the Proximity Key/Card near the sensitive field of the Reader — until all the LEDs turn OFF.
2.
Remove the Key/Card to Disarm the System.
OFF OFF
OFF
ON
NORMA8/
NORMA4
1.
Hold the Proximity Key/Card near the sensitive field of the Reader.
2.
Remove the electronic key from the sensitive area of the reader within half a second to switch
off all the LEDs. This will switch off the system.
Arm — Global
Mode
OFF
ABSOLUTA, KYO320,
KYOUNIT, NORMA
1.
Hold the Proximity Key/Card near the sensitive field of the Reader — until the Red LED turns ON.
2.
Remove the Key/Card to Arm the System in Global Mode.
ON
OFF
OFF
ON
NORMA8/
NORMA4
1.
Hold the Proximity Key/Card near the sensitive field of the Reader.
2.
Remove the electronic key from the sensitive area of the reader within a maximum of half a second
to switch on the RED LED. This will switch on the system.
Arm — A (B)
Mode
OFF
ABSOLUTA,
KYO320, KYOUNIT,
NORMA
1.
Hold the Proximity Key/Card near the sensitive field of the Reader. The LEDs will light in turn (at
2 second intervals).
2.
Remove the Key/Card when the Yellow (Green) LED turns ON. At this point, the Red LED will
also turn ON and the System will Arm in A (B) Mode.
ON
ON
(OFF)
OFF
(ON)
Arm — A Mode
ON
NORMA8/
NORMA4
1.
Hold the Proximity Key/Card near the sensitive field of the Reader. The LEDs will light in turn (at
1 second intervals).
2.
Remove the Key/Card when the Yellow and/or Green LEDs turns ON.
3.
Bring the electronic key into the sensitive area of the reader and remove it within a maximum of
half a second. The RED LED will switch on as well, and the system will go into mode A, B or A+B.
ON
ON
OFF
Arm — B Mode
ON
OFF
ON
Arm — A+B
Mode
ON
ON
ON