Содержание academy 4

Страница 1: ......

Страница 2: ...been developed and made according to the highest standards of quality reliability and performance adopted by BENTEL SECURITYsrl To make sureyoursystemcontinuestoworkasintended youmusttestyour system e...

Страница 3: ...PAD 15 Basic options from standby status 15 Global arming 16 Global disarming 16 Type A or Type B arming 16 Zone bypass 16 View armed partitions 17 View bypassed zones 17 Menu Options from keypad 18 R...

Страница 4: ...all Calls 22 Superkeys 23 Instant alarm call 23 View Alarm Memory 23 Trouble Viewing mode 24 APPENDIX 25 Zones insert 25 Programming sheets 25 Figure 1 Academy4 8 Academy8 L components 4 Security Sys...

Страница 5: ...ephone numbers The main features of the Panel are described in this manual Your Installer will provide further details for proper use of the system Figure 1 shows keypads key reader and digital key Di...

Страница 6: ...des 23 Codes are available for the user The Installer can assign one of the 5 Code Types DISABLED MAIN USER USER DURESS PATROL to each of the 23 codes Each code can control specific options and partit...

Страница 7: ...cators LEDs Academy4 and Academy8 have no status indicators INDICATOR STATUS OFF ON Mains failure Panel powered by battery Mains supply to Panel OK OFF ON Battery OK Low battery or battery trouble OFF...

Страница 8: ...rouble type Trouble Viewing Mode running Ready ON OFF Fast flashing Ready to arm arming will not generate an alarm At least one unbypassed zone is in alarm status arming will generate an alarm Panel i...

Страница 9: ...1 Enable Disable Auto arming Key 2 Enable Disable Teleservice Key 3 Overtime Request Key 4 Teleservice Request Key 5 Enable Disable Silent keypad Key 6 Enable Disable Hidden zone status on keypad Key...

Страница 10: ...send re corded voice messages to the programmed telephone numbers r PATROL Codes are enabled for Global arming disarming PATROL Code PINs can disarm partitions temporarily Partitions disarmed by a PA...

Страница 11: ...ongoing call will be interrupted and the call queue will be cleared Press the digital key button to scan the 4 configurations of the LEDs Global arming Red LED ON all the partitions controlled by the...

Страница 12: ...fol lowing Red LED ON means that at least one of the partitions controlled by the key reader has been armed Red LED OFF means that all the partitions controlled by the key reader are disarmed Amber LE...

Страница 13: ...rm all the partitions controlled by the digital key and key reader in use Step 1 Insert a valid digital key into any key reader all 3 LEDs will go OFF Step 2 Extract the digital key the controlled par...

Страница 14: ...on Flashing on the Green LED indicates violation on at least one zone door or window open therefore arming will generate an alarm Stop alarm To stop an alarm Insert a valid digital key into any key re...

Страница 15: ...ntrol 2 options as per the table below Options that require a Code PIN will only affect the partitions controlled by the Code PIN and the keypad in use OPTION PROCEDURE Global arming Enter Code PIN th...

Страница 16: ...If a Patrol Code PIN is used the disarmed partitions will rearm automat ically when the Patrol time ends DURESS Code PINs should only be used when the User s personal safety is at risk DURESS Code PIN...

Страница 17: ...f access View armed partitions Step 1 Press to view the armed partitions The key will flash The current partition status armed disarmed will be shown on keys through assigned respectively to partition...

Страница 18: ...pad r Alarm Device Test r Program Code PIN r Stop Alarms r Stop Calls The Options will affect the partitions controlled by the Code PIN and key pad in use Reset Alarm Memory Code PIN All zone alarms w...

Страница 19: ...rvice option Panel enabled for incoming Teleservice calls before the Installer activates Teleservice Key toggles Teleservice Step 1 Press when key is ON to enable Teleservice Step 2 Press when key is...

Страница 20: ...ch confirms acceptance of the Teleservice Request Enable Disable Silent keypad Code PIN The Silent option can be enabled disabled on each keypad When this option is enabled the keypad will not emit an...

Страница 21: ...Stop alarm event and the Stop all Calls procedures refer to the following para graphs Change User PIN Main Users can change their own PINs However Main Users cannot change the PINs of other Main Users...

Страница 22: ...ted by a sensor Step 1 Enter Code PIN Step 2 Press Step 3 Press All the alarm signalling devices of the partition will be forced into standby status New alarms on the partition will be ignored This st...

Страница 23: ...all Event calls can be activated from the keypad by pressing the correspond ing key for approximately 4 seconds The icon on the key identifies the alarm type Fire alarm Danger alarm Police The Digital...

Страница 24: ...power fuse blown Key 4 OFF ON Panel powered by mains Mains failure Panel powered by battery Key 7 OFF ON Battery OK Low battery or battery trouble Key B OFF ON Communication bus OK Communication bus...

Страница 25: ...ox see figure 5 in this way it will be on hand when zone identifica tion is required Programming sheets The User should refer to the programming sheets to be filled in by the in staller when informati...

Страница 26: ...004 Patrol 0004 Yes Yes Yes Yes A A A A A A A A No This is the Code identifier Number Description This is the Code label Type This is the Code Type programmed by the Installer PIN This is the Personal...

Страница 27: ...15 16 16 Add This is the Device Address keypad or key reader No This is the identifier number keypad or key reader Partitions These are the partitions the keypad can control Red These are the partitio...

Страница 28: ...o arming Main User code Enable Disable Teleservice Answer Main User code Overtime request Main User or User code Send Teleservice Call Main User code Enable Disable Silent keypad Main User code Enable...