Global arming
<Code PIN>+
This option will arm all the partitions controlled by the Code PIN and key-
pad in use.
+
The
Green READY LED
must be
ON
(no zones violated) before starting
the procedure.
Step 1
Enter a Main User, User, Duress or Patrol Code PIN.
Step 2
Press
to arm all the partitions controlled by the Code PIN and keypad
in use.
The keypad buzzer will signal the elapsing delay (EXIT TIME).
Global disarming
<Code PIN>+
This option will disarm all the partitions controlled by the Code PIN and
keypad in use.
Step 1
Enter a Main User, User, Duress or Patrol Code PIN.
Step 2
Press
to disarm all the partitions controlled by the Code PIN and key-
pad in use.
All the Signalling Devices (activated by alarm on the partition) will be
forced into standby status when the partition is disarmed.
If a
Patrol
Code PIN is used, the disarmed partitions will rearm automat-
ically when the
Patrol time
ends.
+
DURESS
Code PINs should only be used when the User’s personal safety
is at risk.
DURESS
Code PINs will disarm the system, and at the same
time activate the Digital Communicator and Voice Dialler.
Type A or Type B arming
<Code PIN>+
or
During the programming phase each Code will be configured for Type A
arming and Type B arming. The configuration determines the partitions
that will arm and disarm for a Type A or Type B arming request.
Example: Type A arming configuration = arm partitions 1 and 4; disarm
partitions 2 and 3.
Step 1
Enter a Main User, User or Duress Code PIN.
Step 2
Press
or
to arm with Type A or B arming configuration, as per the
request.
Zone bypass
<Code PIN>+
+zone no.
This option allows the User to bypass specific zones. Only zones assigned
to the partitions controlled by the Code PIN and keypad in use can be by-
passed / unbypassed.