8
Universal Cellular Communicator
Identification of parts
Numbers given in bold in this manual refer to the main parts of the communicator shown in figure 1 and 2, and the table on page 2.
Description of jumpers
Interface type between SPT (Supervised Premises Transceiver)
and AS (Alarm System)
Proprietary interface
ATS (Alarm Transmission System)
SINGLE PATH
Alarm Transmission System performance
SP4 for digital messages SP2 for vocal/text messages
Average transmission time
D3 (20 s)
D2 (60 s)
Maximum transmission time
M3 (60 s)
M2 (120 s)
Reporting time
T4 (180 s)
T2 (25 h)
Substitution security
S2
S0
Information security
I3
I0
Table 3 – EN 50136-1:2012 and EN 50136-2:2013 specifications.
Jumper
Position
Description
PST
oo
Reserved (leave open).
USB
oo
The communicator behaves as a USB Device (factory setting).
//
The communicator behaves as a USB Host.
TMP
oo
Anti-tamper function enabled (factory setting).
//
Anti-tamper function disabled.
UFC
oo
Future use.
JP2
(versions with
housing only)
No limit to communicator current draw (factory setting).
Communicator current draw limited to 230 mA.
!
Backup battery required!
Table 4 – Description of jumpers.