![BENSON BENDX ACHW 34 Скачать руководство пользователя страница 29](http://html1.mh-extra.com/html/benson/bendx-achw-34/bendx-achw-34_operation-manual_2735271029.webp)
Equipment
12.
Design safe es, oper on set points and general design
1/`
High Pressure Cut Out (3000 kPa) Auto reset
2/
Low Pressure Cut Out (50 kPa) Auto reset
3/
High discharge compressor temperature protec on 100`C (Error codes on tank & compressor sensors failure)
4/
Circula on Pump Material Bronze
5/
Circula on
fl
ow rates BENDX ACHW 41 Low 5.6 l/min (+/- 15%) High 8.2 l/min (+/- 15%)
Other units
fl
ow rates to be advised
6/
No Supplementary hea ng is required
7/
Low Temperature Class A opera on
8/
Heat exchanger is a triplex type, in the event of a water leak or refrigerant leak the system is
fi
ed with a leak hole to atmosphere.
9/
The system must be install to AS/NZS 3500.4 and all relevant state and territory regulations.
10/
Defrost/deice occurs as the heat pump is absorbing heat from the atmosphere and at low
ambient condi ons frost or ice may form. The system will autom cally manage this as
follows:
1
st
defrost point is set at -8`C it must be -8`C for 30seconds, this checked from 35 minutes to
one hour of con nues opera on
2
nd
defrost point is set at -4`C it must be at -4`C for 3 minutes, this is checked from 35 minutes
of compressor opera on
ues or accumu
ve me.
3
rd
defrost point is set at -2`C it must be at -2`C for 3 minutes, this is checked from 35 minutes
of compressor opera on
ues or accumu
ve me.
All subsequent points are set at the 3
rd
defrost point sequence.
11/
So Star g is required in all system to a maximum of 45amps inrush, this should be compliant to most
State or Territory star g current regula ons
27
Содержание BENDX ACHW 34
Страница 1: ...AIR CONDITIONER WATER HEATER OPERATION MANUAL...
Страница 7: ...3 OUTLINES AND DIMENSIONS BENDX ACHW 34 BENDX ACHW 34 5...
Страница 8: ...3 OUTLINES AND DIMENSIONS BENDX ACHW 41 BENDX ACHW 51 BENDX ACHW 41 BENDX ACHW 51 6...
Страница 9: ...3 OUTLINES AND DIMENSIONS BENDX ACHW 65 BENDX ACHW 65 7...
Страница 11: ...4 WIRING DIAGRAMS INDOOR UNIT OUTDOOR UNIT Model 34 41 and 51 Model 34 41 and 51 9...
Страница 12: ...4 WIRING DIAGRAMS INDOOR UNIT OUTDOOR UNIT Model 65 Model 65 10...