System
11.
Installa on
Recommended
PTR Valve and Tempering Valves are
ed (hot water safety 50`C or below temperature control)
In line
fi
lter or strainer
fi
ed to the cold water in feed to the tank
Required
1/
Depending on the tank manufacturer
850 kPa P and T Valve be
fi
ed to the Tank
2/
Mains pressure regulator be
fi
ed and set to 500kPa (Check each states requirements, to be
installed by a Licensed Plumber)
3/
Sensor to be
fi
ed to the bo
m po
on of the Hot Water Tank. (Supplied with the system)
Temperature Set
58`C (+/-3%) with the sensor
fi
ed to the lower sensing point
O
ff
Peak /manual turning on and o
ff
of the hot water system
The Benson Global has a lead on the indoor unit that when closed by a relay or switch will keep the
hot water system ac vated.
All other normal opera ons are available
off
the Infra Red or Wall Controller.
Ambient condi ons and Performance Heat Pump Hot Water
In Lower ambient c
ons the system performance will be reduced, the system uses the outdoor
unit to absorb heat from the atmosphere, if the temperature is low the heat absorp on will be less
and the hot it is the more heat is absorbed and the performance is naturally higher.
Do not be alarmed about frost appearing on the system in low ambient condi ons, the system will
autom cally defrost /deice the system, this takes 5-7minutes and whooshing of refrigerant maybe
heard during this cycle, once again this normal and do not be alarmed.
On Heat Pump hot water the indoor unit also has refrigerant pass through it, so some cracking maybe
heard as the indoor coil (metal) expands in the ABS indoor casing.
Australian Standards (Major) that we comply to
AS 2712 and AS 3498 Water Mark and Heat Pump
AS 3823 MEPS Minimum Energy Performance
AS 5125 Heat Pump Performance te
AS 1677 Refrigerant Design
Voltage
BEN ACHW Tank approval
The Everlast 250GS is that tank that must be fitted to the BEN ACHW to gain ORER rebates(STC),
all modelling has been carried out on the Everlast 250GS tank.
of the unit
220/24/- 10%
50Hz frequency
Single Phase
26
Содержание BENDX ACHW 34
Страница 1: ...AIR CONDITIONER WATER HEATER OPERATION MANUAL...
Страница 7: ...3 OUTLINES AND DIMENSIONS BENDX ACHW 34 BENDX ACHW 34 5...
Страница 8: ...3 OUTLINES AND DIMENSIONS BENDX ACHW 41 BENDX ACHW 51 BENDX ACHW 41 BENDX ACHW 51 6...
Страница 9: ...3 OUTLINES AND DIMENSIONS BENDX ACHW 65 BENDX ACHW 65 7...
Страница 11: ...4 WIRING DIAGRAMS INDOOR UNIT OUTDOOR UNIT Model 34 41 and 51 Model 34 41 and 51 9...
Страница 12: ...4 WIRING DIAGRAMS INDOOR UNIT OUTDOOR UNIT Model 65 Model 65 10...