BENSON BENDX ACHW 34 Скачать руководство пользователя страница 28

 

System

11.

 Installa on 

Recommended 
PTR Valve and Tempering Valves are 

ed (hot water safety 50`C or below temperature control) 

In line 

lter or strainer 

ed to the cold water in feed to the tank 

 
Required 
1/  

Depending on the tank manufacturer 
850 kPa P and T Valve be 

ed to the Tank 

2/ 

Mains pressure regulator be 

ed and set to 500kPa (Check each states requirements, to be 

installed by a Licensed Plumber) 

3/ 

Sensor to be 

ed to the bo

m po

on of the Hot Water Tank. (Supplied with the system) 

 
Temperature Set  
58`C (+/-3%) with the sensor 

ed to the lower sensing point 

 
O

 Peak /manual turning on and o

 of the hot water system 

The Benson Global has a lead on the indoor unit that when closed by a relay or switch will keep the 
hot water system ac vated. 
All other normal opera ons are available 

off

 the Infra Red or Wall Controller. 

 
Ambient condi ons and Performance Heat Pump Hot Water 
In Lower ambient c

ons the system performance will be reduced, the system uses the outdoor 

unit to absorb heat from the atmosphere, if the temperature is low the heat absorp on will be less 
and the hot it is the more heat is absorbed and the performance is naturally higher. 
Do not be alarmed about frost appearing on the system in low ambient condi ons, the system will 
autom cally defrost /deice the system, this takes 5-7minutes and whooshing of refrigerant maybe 

heard during this cycle, once again this normal and do not be alarmed. 

On Heat Pump hot water the indoor unit also has refrigerant pass through it, so some cracking maybe 
heard as the indoor coil (metal) expands in the ABS indoor casing. 
 
Australian Standards (Major) that we comply to 
AS 2712 and AS 3498 Water Mark and Heat Pump 
AS 3823 MEPS Minimum Energy Performance  
AS 5125 Heat Pump Performance te

 

AS 1677 Refrigerant Design  
 
Voltage

BEN ACHW Tank approval

The Everlast 250GS is that tank that must be fitted to the BEN ACHW to gain ORER rebates(STC),

all modelling has been carried out on the Everlast 250GS tank.

 of the unit 

220/24/- 10%  
50Hz frequency 
Single Phase 
 

26

Содержание BENDX ACHW 34

Страница 1: ...AIR CONDITIONER WATER HEATER OPERATION MANUAL...

Страница 2: ...ury or death Disconnect and lock off power before servicing equipment SPECIAL FEATURES OUTLINES AND DIMENSIONS WIRING DIAGRAMS SAFETY PRECAUTIONS BEFORE INSTALLATION INSTALLATION REMOTE CONTROLOPERATI...

Страница 3: ...with refrigerant pipe submerge into water tank ACHW incorporate high efficiency Twin copper tube heat exchanger that circulates the the water in and out of the tank This unique safety feature renders...

Страница 4: ...gn filter is slide out type which can be easily removed at the air inlet grille for cleaning WIRELESS REMOTE CONTROL The compact LCD transmitter is able to operate the air conditioner unit within the...

Страница 5: ...emperature setting Operation display To set the desined room temperature press the button to increase or decrease the set temperature The temperature setting range is 16 31 C Summer and winter 24 C C...

Страница 6: ...60 C Cooling and Hot Water You operate your system as a normal air condi oner and while you are doing so it he ng your hot water for Free ng and Hot Water Because of the unique design of the system th...

Страница 7: ...3 OUTLINES AND DIMENSIONS BENDX ACHW 34 BENDX ACHW 34 5...

Страница 8: ...3 OUTLINES AND DIMENSIONS BENDX ACHW 41 BENDX ACHW 51 BENDX ACHW 41 BENDX ACHW 51 6...

Страница 9: ...3 OUTLINES AND DIMENSIONS BENDX ACHW 65 BENDX ACHW 65 7...

Страница 10: ...NK 8 This tank is a guide only for connection installation may vary with tanks supplied Specifications subject to change for product improvements 650kPa P and T Valve Be fitted Recommended filter or s...

Страница 11: ...4 WIRING DIAGRAMS INDOOR UNIT OUTDOOR UNIT Model 34 41 and 51 Model 34 41 and 51 9...

Страница 12: ...4 WIRING DIAGRAMS INDOOR UNIT OUTDOOR UNIT Model 65 Model 65 10...

Страница 13: ...code Green and yellow Earth Blue Brown Live Neutral As the colours of the wires in the mains lead of this appliance may not correspond with the coloured markings identifying the terminals in your plu...

Страница 14: ...fire ignition Confirm drainage piping is connected properly If it is not connected perfectly it may cause water leakag this is the installers Liability and should be checked at commisioning Confirm th...

Страница 15: ...6 INSTALATION 13 Cycle Water Inlet Cold Water Inlet Cycle Water Outlet Pressure Regulator Valve is required 500kPa Mixing Valve V 50 C...

Страница 16: ...cooler air can be evenly distributed See fig 1 Ensure that air discharge is not short circuited with air intake Ensure that wall is sufficiently strong rigid flat perpendicular and vibration free Wher...

Страница 17: ...in and distribute plenty of air thus lowering the condensing temperature A place capable of bearing the weight of the outdoor unit and isolating noise and vibration A place protected from direct sunl...

Страница 18: ...he desired location on the wall and mark the holes location accordingly Ensure that the minimum maintenance and servicing space at the top left and right side of the units is reserved Ensure also the...

Страница 19: ...ressor or any moving parts of fan motors The field wires from the indoor unit must be clamped on the wire clamp 4 REFRIGETANT PIPING MODEL PIPE D mm IMPERIAL DLE RIGED DIE A mm 6 35 1 4 1 3 9 52 3 8 1...

Страница 20: ...500 microns note R290 connected to Hhandle evacuate to bottle tap Refer to figure at right to connect stop valve gas charging hose mixing valve and vacuum pump Use vacuum pump 76cmHg stop valve liquid...

Страница 21: ...ons foreign matters etc Every 12 months Every 12 months Compressor 1 No maintenance needed if refrigerant circuit remains sealed However check for refrigerant leak at joints and fittings Every 12 mont...

Страница 22: ...se of Loose connections Indoor temperature sensor failure E1 Check if sensor is short circuit Indoor pipe temperature sensor failure E2 Check if sensor is short circuit Outdoor system failure E4 Outdo...

Страница 23: ...tive 2 Non condensable gases in refrigerant circult e g oil 3 Obstructed air intake discharge 4 Short circuiting of hot air at condensing unit Too low Too high Normal A little Low A little High Data P...

Страница 24: ...itioner is disconnected from main power source e Fuse blown or circuit brealer off ii Diagnosis of Refrlgerant Circuit Application There might be some cases where the unit starts running but does not...

Страница 25: ...on the flare surface however be very careful not to get any in the inside of the pipe can cause blockages minimal can be used on the thread torque settings still apply The torque Settings liquid 37 N...

Страница 26: ...w these may need to be bridge for charging Start the system and continue charging very slowly as the gas maybe sucked in very quickly avoid Liquid refrigerant going directly into the compressor Check...

Страница 27: ...line lter supplied warranty void if not Cold water in Water is taken from a ng approximately 300mm above the om of the tank and is heated and returned into a ng 100mm lower Air Purging Leave the retur...

Страница 28: ...performance will be reduced the system uses the outdoor unit to absorb heat from the atmosphere if the temperature is low the heat absorp on will be less and the hot it is the more heat is absorbed an...

Страница 29: ...and all relevant state and territory regulations 10 Defrost deice occurs as the heat pump is absorbing heat from the atmosphere and at low ambient condi ons frost or ice may form The system will autom...

Страница 30: ...operated and maintained as per the instruc s supplied 3 The warranty covers the Benson Global system only and not any addi onal parts supplied during the installa on including the tank 4 Warranty is...

Страница 31: ...essed in the Warranty Terms and con ons 4 Claims for damages caused directly or indirectly by leakage from the system 5 All damages or breakages is not covered by this warranty and should be added to...

Страница 32: ...elow In the event the system has water leaking from the top sec on of the unit a Benson Global authorized agent should be called to check the system Do not a mpt to repair the system yourself this can...

Страница 33: ...s that A3 refrigerants R290 shall be permitted only is systems with a refrigerant change of up to 1 5kg for each individual system provided sudden loss of refrigerant could not raise the concentration...

Отзывы: