8.1.6 Null balance of the angle of inclination
- Place the device onto a plane surface and press the key
4
for > 5 seconds until the "Z"
symbol starts flashing on the digital display
2
.
- Press the key
4
again to store the "+SET" value.
- Turn the device by 180° and press the key
4
again to store the "-SET" value. The angle of
inclination has been balanced to null and the "Z" symbol is shown on the digital display.
- Press the key
4
again for > 5 seconds to exit the setting. The "Z" symbol disappears from
the LC display.
8.1.7 Compass bearing (orientation)
- Press the key
4
to display the angle of inclination and the compass bearing.
- The compass bearing is indicated continuously on the digital display
2
.
- To determine the cardinal direction, hold the device horizontally. As soon as the angle of
inclination e/- 20°, the compass bearing indication shows "- - -" and it is not possible
to take a bearing.
- Hold the marking
9
for the compass bearing in the direction which you would like to
determine. The direction is displayed in degrees:
0° = North, 90° = West, 180° = South, 270° = East
- Please observe that metallic objects or live conductors might affect the measuring accuracy
of the device.
insolation
►
angle of inclination
►
compass bearing
►
8.2 Data logger (measured value memory) with real-time clock
The BENNING SUN 2 can store up to 5000 data records consisting of the values for insola-
tion (solar irradiance), module temperature and ambient temperature. Each data record will be
provided with a time / date stamp. The measuring data can be read out via the integrated USB
interface and by means of a download software. The measuring interval (time between two
measurements) of the BENNING SUN 2 can be set from 1 minute to 60 minutes in increments
of one minute.
8.2.1 Data logger set-up
The set-up allows the user to set the measuring interval, the memory mode and to delete all
data records.
- Press the key
7
for > 5 seconds to call the data logger. "LOG" appears on the digital display
2
.
- Alternately, the display shows the occupied / free memory space as well as the battery
voltage / the measuring interval in minutes.
- To set the measuring interval (1 minute to 60 minutes), press the key
7
again for > 5
seconds. Display: "Int". Press the key
4
or key
5
to increase or decrease the value in
increments of one minute.
- Press the key
3
to display the memory mode. Display: "dAtA". Press the key
4
or key
5
to select "StOP" (if the memory is full) or "rOLL" (if you want to overwrite the oldest measured
values continuously).
- Press the key
3
again to delete the memory. Display: "dEL". Select "yES" or "nO" by
pressing the
4
or
5
keys to delete the entire memory.
- By means of the key
7
(OK), it is possible to store the setting at any time and to exit the data
logger.
- Press the key
3
or
4
to exit the data logger.
occupied memory
space
battery voltage
free memory space
measuring interval
(1 min. to 60 min.)
▲
alternating display
▲
└──────────────┘