03/ 2012
BENNING SUN 2
10
All measuring results are displayed on the large LC display.
- Storage capacity of the data logger: 5000 data records, including the values for insolation,
module temperature and ambient temperature as well as a time / date stamp
- integrated real-time clock
- Interface: USB
- Dimensions of the device:
(L x W x H) = 150 x 80 x 33 mm
- Weight of the device:
265 g without temperature sensors / USB cable
347 g including temperature sensors / USB cable
6. Ambient conditions
- The BENNING SUN 2 is intended for measurements under dry ambient conditions,
- Maximum barometric height for measurements: 0 m to max. 2000 m
- Contamination level: 2
- Protection category: IP 40 (DIN VDE 0470-1, IEC/ EN 60529)
4 – first index: protection against access to dangerous parts and protection against solid
impurities of a diameter > 1.0 mm
0 – second index: No protection against water
- EMC: IEC/ EN 61326,
- Operating temperature and relative air humidity:
For operating temperatures from 0 °C to 50 °C: relative air humidity lower than 80 %, non-
condensing
- Storage temperature: The BENNING SUN 2 can be stored at temperatures between - 20 °C
and + 60 °C (air humidity 0 to 80 %). During storage, the batteries must be removed.
7. Measuring ranges
Note: The measuring accuracy is specified as the sum of:
- a relative part of the measured value and
- a number of digits (i.e. counting steps of the last digit).
This measuring accuracy applies to temperatures from 0 °C to 50 °C and a relative air humidity
lower than 80 %.
7.1 Insolation
Measuring range
Resolution
Measuring accuracy
100 Wm² to 1250 Wm²
1 W/m²
± (5 % + 5 digits)
30 BTU/h/ft² to 400 BTU/h/ft²
1 BTU/h/ft²
± (5 % + 5 digits)
7.2 Module temperature and ambient temperature
Measuring range
Resolution
Measuring accuracy
- 30 °C to + 125 °C
1 °C
± (1 % + 1 digit)
- 22 °F to + 257 °F
1 °F
± (1 % + 1 digit)
7.3 Angle of inclination
Measuring range
Resolution
Measuring accuracy
0° to 80°
1°
± 2°
7.4 Compass bearing (orientation)
Measuring range
Resolution
Measuring accuracy
0° to 360°
1°
± 10°
8. Measuring with the BENNING SUN 2
8.1 Preparing the measurement
Operate and store the BENNING SUN 2 at the specified storage and operating temperatures
only!
- Strong sources of interference in the vicinity of the BENNING SUN 2 might involve unstable
readings and measuring errors.
Before commissioning, always check the device as well as all connecting
cables for damages.