maintenance measures listed and other maintenance work can only be performed by our authorized 

technicians. 

Note: Shut down and disconnected the power supply before maintenance to avoid possible 

personal injury and /or damage to the system. 

5.1 Cleaning

 

Clean the outer surface of the system with a soft damp cotton ball at least once a week. You 

can use neutral cleaners and clean water to wipe off the stains. It is strictly forbidden to use acidic 

or alkaline cleaners. 

After each maintenance, you need to clean the surface of the system carefully with medical 

alcohol to keep it clean and dry. 

 

5.2 Troubleshooting 

Problem 

Possible reason 

Solution 

No Display 

The power cord wasn’t 

connected well 

Check the connection of the 

power cord 

The power button is not 

pressed 

Press the power button 

There is no response when press the 

screen 

System error 

Please contact our customer 

service for assistance 

The system can not enter into the main 

interface 

System error 

Please contact our customer 

service for assistance 

Insufficient disinfectant notes on the 

screen 

Insufficient disinfectant 

Please add enough 

disinfectant in time 

No temperature detection display on the 

left side of the screen 

Thermal imaging camera 

damaged 

Please contact our customer 

service for assistance

 

The disinfectant is sufficient, but no 

disinfectant coming out 

Water pump damaged 

Please contact customer 

service for assistance 

Screen display “Please insert the USB 

flash drive first” 

USB disk is not inserted 

Please insert the USB disk 

into the USB1 port 

 

 

 

Содержание IRD 120A

Страница 1: ...Operating Instructions Thermal imaging camera disinfection system Model No IRD 120A English Before operating this unit please read these instructions completely ...

Страница 2: ...ure of the system 3 2 3 Specification 4 3 Installation 5 4 Instruction of use 7 4 1 Turn on the system 7 4 2 Temperature detection 7 4 3 Disinfection 8 4 4 Real time monitoring 8 4 5 Temperature calibration and alarm setting 9 5 Maintenance and troubleshooting 9 5 1 System cleaning 10 5 2 Troubleshooting 10 ...

Страница 3: ...ry So it is necessary to read the instructions of safety requirements and operation procedures before turn on the system Except the authorized technicians anyone else is not allowed to fix the system especially the inside of the system like power supply unit touch screen and etc There is high voltage risk inside the system Make sure the voltage of system is same as your country standard AC100 240V...

Страница 4: ...detection the red LED light flashes with voice alarm when anyone with high temperature walks in It detects people who has fever automatically which reduces the workload of temperature detection greatly The spraying nozzles in the channel will spray the disinfectant from different angles it only takes one second to kill virus or bacteria in the channel It is easy to install and also very simple saf...

Страница 5: ... display thermal imaging camera and etc Figure 2 1 Back of the system Figure 2 2 Front of the system No Name No Name 1 USB port 6 Infrared thermal imaging camera 2 Display 7 The right panel of the system 3 Power button 8 Tank of disinfectant 4 The left panel of the system 9 Disinfection area 5 Power in 10 Temperature detection area 2 4 1 5 8 9 10 6 3 7 ...

Страница 6: ...oid7 0 Working temperature 0 45 Information record NO Detection distance 1 5m Detection accuracy 0 3 0 5 Lack of liquid Alarm Yes Power 200W Dimension 1m 1m 2 2m Basic functions Record and query disinfection infrared thermal imaging temperature detection and abnormal alarm Optional functions Hand induction disinfector and alcohol concentration detection ...

Страница 7: ...ght hexagon socket screws provides by the manufacture Figure 3 1 Main shell Step 2 Place the disinfectant tank on the right side of the IRD120A systemmain body as shown in the system structure picture insert the hard water pipe on the right shell of the main body into the quick connector of the disinfectant tank Figure 3 2 Disinfectant tank Steps 3 You will find the water pump connection cable fro...

Страница 8: ... 20L please check whether the disinfectant is sufficient or not after use Step 5 Connect the power cord to the power in port on the left shell of the main body and connect the USB disk we offered to the USB1 port on the left shell of the main body Figure 3 5 Power in port Figure 3 6 USB1 port for USB disk Step 6 Place the pad to the right position in front of the channel The distance from the pad ...

Страница 9: ...see the display as below picture Figure 4 1 Welcome page of screen 4 2 Temperature detection When people walk to the temperature detection point looking up at the green indicator light in picture 4 3 it will auto focus and the system will announce the temperature value by voice When the body temperature exceeds the alarm threshold the red LED light flashes and voice alarm as well Figure 4 2 The gr...

Страница 10: ...e 4 3 Photoelectric sensor and spraying nozzles 4 4 Real time monitoring The staff can watch the screen and monitor the body temperature of people who walk through in real time Figure 4 4 Abnormal Figure 4 5 Abnormal Note 1 Lowest temp highest temp average temp shows the current body temperature for the people who walk in 2 The camera at the top of the channel will take pictures with thermal imagi...

Страница 11: ...perature difference by sliding the temperature value on the screen as Figure 4 6 shows For example the referenced temperature measured by thermometer of the people is 36 C and the temperature measured by IRD 120 is 35 C Then you can calibrate the temperature for IRD 120 system by clicking the icon on the screen and slide the temperature value on the left side as Figure 4 6 shows choosing 1 0 C and...

Страница 12: ...e power cord wasn t connected well Check the connection of the power cord The power button is not pressed Press the power button There is no response when press the screen System error Please contact our customer service for assistance The system can not enter into the main interface System error Please contact our customer service for assistance Insufficient disinfectant notes on the screen Insuf...

Отзывы: