10
DIP2
Bloc of flats
The bloc of flat function is enabled or disabled.
Off: the bloc of flat function is disabled.
On: the bloc of flat function is enabled.
The Step-by-Step signal or the transmitter signal has no effect
during opening.
DIP3
TCA Special
The TCA special is enabled or disabled.
Off: Special TCA function is disabled.
On: Special TCA function is enabled.
If a PP control signal is sent in the first 5 seconds of the TCA
calculation, the TCA is ignored and the closing operation is
started.
If the PP control signal is sent after the first 5 seconds and
before the preset TCA time has elapsed, the time is reset and
the new TCA counting starts.
DIP4
P.P. : operating
mode
The operating mode of the “P.P. button” and of the transmitter
is selected.
Off: Operation: OPEN>STOP>CLOSE>STOP>
On: Operation: OPEN>CLOSE>OPEN>
DIP5
Radio channel II
/LOCK
The operating mode of the output to SCA terminals is selected
(for a correct operation of the logics see the table “Inputs/
outputs functions – SCA-SCA paragraph” at page 4).
Off: Impulse output for the control of the Lock card for electric
lock
On: Impulse output, radio channel II of the incorporated
receiver
DIP6
Step-by-Step:
3-STEP
mode
The 3 steps is enabled or disabled.
On: The PP control sequence is the following:
OPEN>STOP>CLOSE>OPEN>STOP>CLOSE>…
Off: The control sequence is the one preset by DIP 4.
NOTE: it operates with DIP 4 only on OFF.
TRIMMER OPERATIONS
TW
The maximum duration of the opening and closing operation is adjusted.
It should be preset at around 4sec more compared to the actual stroke time of the
system.
The adjustment varies from 3 sec minimum to 180 sec maximum.
TCA
The automatic closure time can be adjusted.
The adjustment varies from 3 sec minimum to 180 sec maximum.
With TCA trimmer entirely turned clockwise, the LED DL2 (green) switches off
and the TCA is deactivated.
SERVICE MAN MODE
By moving all DIPs to ON, the control unit switches to the SERVICE MAN mode.
The PHOT input takes the CLOSE Button function (connect the push-button with a N.O.
contact).
The PP input acts as OPEN Button (connect the push-button with a N.O. contact).
The SWO and SWC inputs are disabled.
During the entire operation, the OPEN/CLOSE push-buttons must be kept pressed. When the
STOP input opens, the motor stops.
By pressing the OPEN/CLOSE buttons simultaneously, the motor stops.