20
-
Note: Very important
1.
Always turn off the device if it has been repaired or maintained.
2.
When sending the device for inspection, make sure that the measuring
probes are always in a storage liquid when you send them. If the measuring
probes are dry for 3 to 4 hours, this may affect the following measurements
and lead to incorrect measurements.
HOW TO RINSE A DOSING UNIT
We take the extraction nipples from the acid and chlorine tank.
We put 2 buckets of lukewarm water in the place of the buses
Place the suction nipple in the buckets of water and run the dosing unit for half an hour, the
setting being such that the dosing pump system rotates.
After 30 minutes, remove the suction nipple from the water and let the dosing unit run for
another 5 minutes so that all the water is out of the hoses.
You can now safely ship your dosing unit
Troubleshooting
PROBLEEM
CAUSE
SOLUTION
The screen does not light up
Supply voltage is missing
Stuurspanning
Acid pump does not dose
Switch under the dosing pump
is set to "O"
Set the switch to "1"
pH control settings are wrong:
pH+ while pH is dosed (or vice
versa)
Check the settings
A level indicator is connected
that gives the wrong contact
Disconnect level indicator
A flow switch is connected and
indicates that there is no flow
Check the flow rate and flow
switch (go to the flow switch
setting: no).
The acid pump continues to
dose
Setpoint not yet reached
No action required
Wrong parameter setting: pH +
while pH- is dosed (or vice
versa)
Parameter aanpassen
Relays remain on
Contact the supplier.
Acid pump only doses
occasionally
The acid pump stands for
proportional dosing
No action required
Chlorine pump does not dose
Switch under the dosing pump
is set to "O"
Set the switch to "1"
Rx control settings are incorrect Check the settings