11
11.1) Language
You can set a (different) language. Press the middle button again. Then
use the top or bottom button to navigate to the languages Français,
Castellano, Italian, English, German. You confirm your choice of language
by pressing the middle button.
11.2)
Dosing method: proportional or continuous
Press the bottom button. The setting "Dosing method" is now checked.
Press the center button to activate this setting. You will now see that
the dosing method Prop (= proportional) is selected. Press the middle
button again. The dosing method is now proportional.
Be careful!
You should NOT choose the salt option for the addition of liquid chlorine.
Explanation of the dosing method proportionally:
In the "Proportional" dosing method, the controller continuously goes through a cycle in which:
- pH and chlorine content are measured and stored for 40 seconds (no dosing is
currently used).
- The chlorine (if necessary) is dosed for 2 minutes.
- The pH min (if necessary) is dosed for 2 minutes.
The closer the pH value approaches the setting value, the less
the pump is running.
This dosing method (prop) is recommended for working with liquid chlorine and liquid pH
With this dosing method, pH and liquid chlorine are never dosed simultaneously
Explanation of the dosing method Cont:
- The pumps always run if pH and/or redox setpoint are not reached.
-
If you decide to use this dosing method, the injection point for pH and chlorine should be at
least 2 metres apart.