ELE. - 60
BATTERY EFFICIENCY CONTROL
CHECKING BATTERY CURRENT LOSSES
Connect:
•
The multitester between the negative terminal and the
negative wire of the battery as ammeter in direct current (B)
Fig. 2.
IMPORTANT NOTICE
Since the current losses may be high in case of malfunctioning,
use a high range of the multitester first to prevent damages.
Do no position the ignition switch to ON whilst measuring the
current.
When the panel is off, the current losses must be >/- Ã 2~2.5
mA.
•
Otherwise, find out the source of such absorption by dis
-
connecting the connectors of each utility powered by the
battery directly.
NOTE:________________________________
In the event an anti-theft device is installed, disconnect it
before carrying out the modifications.
+
+
-
mA
2
BATTERY
COPY - Moto GB - Grant Martland - [email protected]