ELE. - 55
STARTER
ACTUATORS
Measure:
•
The resistance between each segment of the switch and
the framework shaft (Fig. D). Reading should be infinite (no
continuity).
Insulation check
Ω infinite
20°C (68°F)
Check:
•
The switch segments for discoloration.
NOTE:________________________________
The presence of discoloured segments in pairs refers to
short circuits of coils that require the replacement of the
starter.
•
Position the framework in a short circuit detector.
•
Switch on the detector and position longitudinally a saw
blade or a thickness gauge for 3 mm (1/8”) above the lami-
nates of the framework coil.
•
Turn the framework by 360°.
NOTE:________________________________
If the saw blade is attracted towards a pole of the frame-
work, the latter has a short circuit and must be replaced.
Check:
•
The permanent magnets in the starter housing.
NOTE:________________________________
Make sure they are not cracked or far away from the hous-
ing.
D
COPY - Moto GB - Grant Martland - [email protected]
Содержание TRK 502
Страница 6: ...1 1 1 COPY Moto GB Grant Martland grantmartland motogb co uk ...
Страница 19: ...2 2 1 COPY Moto GB Grant Martland grantmartland motogb co uk ...
Страница 37: ...3 1 3 COPY Moto GB Grant Martland grantmartland motogb co uk ...
Страница 40: ...3 4 NOTES COPY Moto GB Grant Martland grantmartland motogb co uk ...
Страница 95: ...4 1 4 COPY Moto GB Grant Martland grantmartland motogb co uk ...
Страница 254: ...5 1 5 COPY Moto GB Grant Martland grantmartland motogb co uk ...
Страница 345: ...6 1 6 COPY Moto GB Grant Martland grantmartland motogb co uk ...
Страница 360: ...ELE 16 7 COPY Moto GB Grant Martland grantmartland motogb co uk ...