The ceramic reflector is not
installed in the boiler.
Install the ceramic reflector according to
the user’s manual.
The firing flap in the boiler
is open.
Using the handle of firing flap and cleaner,
close the firing flap and secure it with the
locking screw with plastic head.
Smoke appears in the
fire room or in the fuel
container.
Low chimney draught.
Ensure the inspection of the chimney
draught at the service chimney company. If
the draught value is lower than the required
value (see users manual) the adjustment
of the chimney is required.
Fire door and/or the upper
boiler cover and/or the fuel
container cover are not
closed properly.
Close the fire door and/or the upper cover
of the boiler and/or the fuel container
cover.
The sealing gasket at the
fire door or at the upper
boiler
cover
was
worn
out/damaged
Change the sealing gasket.*
The rubber sealing of the
fuel container cover is
damaged.
Change the rubber sealing.*
The fuel container is empty.
Fill the fuel container with fuel.
The boiler is coated
with smoke particles
in a short period of
time.
Low amount of agitated air.
Raise
the
ventilator
capacity
(see
Instruction Control Unit manual).
The boiler is repeatedly
overheated
Set the boiler capacity to the nominal
capacity (see Instruction Control Unit
manual).
The grate is full of dust and
ash.
Clean the grate.
The ventilator is broken.
Change the boiler ventilator.*
The ash on the grate
forms clogs.
Recommended fuel was not
used for burning.
Fill the container with appropriate fuel (see
chapter 3).
A great quantity of
unburned
fuel
appears
in
the
ashtray.
The fuel dosage is wrong.
Lower the dosage of fuel in the burner (see
the Instruction Control Unit manual).
The fuel used for burning is
wet.
Fill the container with appropriate (dry) fuel.
The power of the ventilator
is wrongly set and the
stream of air blows the fuel
out of the burner.
Lower the ventilator speed (see Instruction
Control Unit manual).
* - this activity can be maintained only by an authorized service company certified by company
BENEKOVterm s.r.o..
Содержание R100
Страница 1: ...1 SERVICE AND INSTALLATION MANUAL FOR CENTRAL HEATING BOILER BENEKOV R100 ...
Страница 8: ...Fig 2 Basic dimensions of BENEKOV R100 boiler ...
Страница 9: ...Fig 3 Basic dimensions of BENEKOV R100 boiler with additional module of fuel bin ...
Страница 30: ...30 Declaration of conformity of boiler BENEKOV R 100 ...
Страница 31: ...31 Original ES declaration of conformity of boiler BENEKOV R 100 ...