AV8OR User’s Guide Appendix
Pub. No D200803000008 Page 7-17 Rev 3 Apr 2009
© Honeywell International Inc. Do not copy without express permission of
Honeywell.
CONNECTION TO AN EXTERNAL
TRAFFIC SOURCE
ZAON XRX - SERIAL SETUP
Configuration of the Zaon XRX
To configure the Zaon XRX, perform the following steps:
•
Using the XRX AIRCRAFT menu, set the aircraft type as
appropriate for your aircraft as described in the ZAON users
Manual.
•
Using the XRX RANGE menu, set the horizontal detection range
to 6 nm radius.
•
Using the XRX ALTITUDE menu, set the altitude limitation to
2500 ft.
•
Using the XRX COM menu, set the third party communications
to PROFILE 1.
o
Verify the XRX configuration switches are set as
described in the XRX Users Guide for third-party output.
•
Press Mute to return to the traffic screen. This screen will show
“PROFILE 1”.
•
Set the configuration switches on the Zaon XRX to the correct
configuration to use the RS-232 output.
Configuration of AV8OR
To configure the AV8OR to receive external traffic data, perform the
following steps:
•
If the Weather Source is set to
Serial
, it must be changed to
Bluetooth or None.
•
From the Aviation Main Menu, tap the
soft key to
open the System Setup Menu.
•
Highlight the
Device Setup
option and tap the
SELECT
soft
key to show the Device Setup page.
•
The AV8OR must be set up so that the Traffic Port is
configured as “
Serial”
. The Type must be set as “
ZAON
Traffic”
.
•
On the Device Setup page, the configuration steps are: