68
Bend-Tech Dragon A150
Troubleshooting Guide
Limit Switch Operation
15
Troubleshooting Limit Switches
Older Dragon A150 models use a normally closed limit switch system. It is possible to bypass
a limit switch to determine if there is a failed limit switch in the circuit. The Operator can also
test for continuity in each loop using a multimeter.
It is possible to bypass a limit switch on the A150 by rerouting the limit switch wiring to
eliminate a limit switch. Unplug a limit switch from the loop and connect the wires from the limit
switches on either side of that switch to “shorten” the loop. Refer to the diagram for reference.
The Operator can also use a multimeter to test each loop for continuity. If a particular loop
shows no continuity it is likely the result of a failed limit switch.
Machine Control and Mach3 Indicate Homing Switch is Triggered
Machine Control and Mach3 can indicate a limit switch is triggered, but the machine is not
resting on a limit switch. If the Operator tests for continuity and finds all limit switches are
operational the next step is to bypass the limit switches. Connect two limit switch leads
together directly at the Control Box, bypassing all limit switches. If Home lights are still lit in
Machine Control and/or Mach3 diagnostics it is either a failed Control Box or Operator’s Panel.
Содержание DRAGON A150
Страница 1: ...A150 Part 1 of 1 Maintenance Troubleshooting Revision 1 English 2020 Bend Tech LLC...
Страница 12: ...xii Bend Tech Dragon A150 Troubleshooting Guide Contents...
Страница 28: ...28 Bend Tech Dragon A150 Troubleshooting Guide Toolhead 03...
Страница 34: ...34 Bend Tech Dragon A150 Troubleshooting Guide Torch 04...
Страница 36: ...36 Bend Tech Dragon A150 Troubleshooting Guide Engraver 05...
Страница 38: ...38 Bend Tech Dragon A150 Troubleshooting Guide Marker 06...
Страница 44: ...44 Bend Tech Dragon A150 Troubleshooting Guide Gate 08...
Страница 48: ...48 Bend Tech Dragon A150 Troubleshooting Guide Trolley 09...
Страница 56: ...56 Bend Tech Dragon A150 Troubleshooting Guide X and Y Axis Maintenance 11...
Страница 72: ...72 Bend Tech Dragon A150 Troubleshooting Guide Limit Switch Operation 15...
Страница 77: ......
Страница 78: ...Bend Tech LLC 729 Prospect Ave Osceola WI 54020 1 651 257 8715 sales bend tech com www bend tech com...