LR1100 Programming Manual V1.2
[Description]
Sets the distance from the beginning of the line to the position at which subsequent
characters are to be printed.
The distance from the beginning of the line to the print position is [(nL
+ nH
×
256
)
×
0.125 mm].
[Notes]
Settings outside the specified printable area are ignored.
In standard mode, the horizontal motion unit (x) is used.
[Reference]
ESC \, GS $, GS \
ESC % n
[Name]
Select/cancel user-defined character set
[Format]
ASCII
ESC % n
Hex
1B 25 n
Decimal
27 37 n
[Range]
0
n
255
[Description]
Selects or cancels the user-defined character set.
When the LSB of n is 0, the user-defined character set is canceled.
When the LSB of n is 1, the user-defined character set is selected.
[Notes]
When the user-defined character set is canceled, the built-in character set is
automatically selected.
n is available only for the least significant bit.
[Default]
n = 0
[Reference]
ESC &
,
ESC ?
ESC & y c1 c2 [x1 d1...d(y
x1)]...[xk d1...d(y
xk)]
[Name]
Define user-defined characters
[Format]
ASCII
ESC & y c1 c2 [x1 d1...d(y
×
x1)]...[xk d1...d(y
×
xk)]
Hex
1B 26 y c1 c2 [x1 d1...d(y
×
x1)]...[xk d1...d(y
×
xk)]
Decimal
27 38 y c1 c2 [x1 d1...d(y
×
x1)]...[xk d1...d(y
×
xk)]
[Range]
y = 3
32
c1
c2
126
0
x
12 (when Font A (12
×
24) is selected)
0
x
9 (when Font B (9
×
17) is selected)
0
d1 ... d(y
×
xk)
255
[Description] Defines user-defined characters.
y specifies the number of bytes in the vertical direction.
c1 specifies the beginning character code for the definition, and c2 specifies the
final code.
x specifies the number of dots in the horizontal direction.