LR1100 Programming Manual V1.2
o The printer is reset or the power is turned off.
GS ( k pL pH cn fn m (cn=48, fn=81)
[Function]
Print PDF417 symbol data in the symbol storage area.
[Format]
ASCII
GS ( k pL pH cn fn m
Hex
1D 28 6B pL pH cn fn m
Decimal 29 40 107 pL pH cn fn m
[Range]
pL = 3, pH = 0
cn = 48, fn = 81
m = 48
[Description]
Encodes and prints the PDF417 symbol data stored in the symbol storage area by
function 80.
[Notes]
• A symbol that size exceeds the print area cannot be printed.
• If there is any an inconsistence in the data of symbol storage area, it cannot be
printed.
o There is no data (function 80 was not executed).
o If [(number of columns × number of rows) < number of codeword] when auto
processing is specified for number of columns and number of rows.
o Number of codeword exceeds 928 in the data area.
• The following data are added automatically by the encode process:
o Start pattern and stop pattern.
o Indicator codeword of left and right.
o The descriptor of symbol length (the first codeword in the data area).
o The error correction codeword calculated by modulus 929.
o Pad codeword.
• When auto processing (function 65) is specified, the number of columns is
calculated by the current print area, module width (function 67), option setting
(function 70), and the codeword in the data area. Maximum number of columns is
30.
• Printing of symbol is not affected by print mode (emphasized, double-strike,
underline, white/black reverse printing, or 90° clockwise-rotated), except for
character size and upside-down print mode.
• This command executes paper feeding for the amount needed for printing the
symbol regardless of the paper feed amount set by the paper feed setting
command. The print position returns to the left side of the printable area after
printing the symbol.
• The quiet zone is not included in the printing data. Be sure to include the quiet zone
when using this function.
GS ( k pL pH cn fn m (cn=48, fn=82)
[Function]
Request to transmit size information of PDF417 data in the symbol storage area