32
Using the Product
Start up
–
To clean the thimerosal in the machine, take cold / hot / ambient / sparkling water 2.5 L each before use this machine first time.
–
The hot water cannot use continues water function.
–
The cold water will flush the pipe about 1 second after take sparkling water, its normal performance.
–
The cooling system will take about 60 to 90 minutes to finish cooling the ICEBANK for first time.
–
The RO filter purifying system will take about 10 to 15 minutes to fill the water box in the machine.
1
. Power on supply water.
All the lamps on the touching screen flashing 3 times. The
machine enters on “first power on model”. If the Hot / Ambient
/ Cold 3 lamps flashing it means the lack of water in the ice
bank tank. The three lamps shut off. It means finish injects
water into the ice bank tank.
2
. Then the Purifying lamp keep lighting, please wait till the
lamp shut off, then the machine quit “first power on model”,
and the sparkling water pump start working.
3
. Turn on the cooling/heating switch to the “I” side. Accor-
ding to the actual requirement start the heating and cooling
functions. The green one is the cooling switch and the red
one is the heating switch. The icon will flash slowly when the
machine is heating or refrigeration.
4
. Open the door. Installation the CO2 cylinder into the ma-
chine. Then the Cylinder lamp stops flashing. The machine
has an external gas connection in the rear; you can supply
appropriate pressure gas (0.4 MPa) through the white PTFE
tubing outside the machine.
5
. Touch the icon to unlock the hot water function, then
you can long press the Hot icon to take hot water.
6
. Long press the Cold/ Ambient/Sparkling icon to take Cold/
Ambient/ Sparkling water.
7
. Touch the Reheat icon to re-hearing the hot water (from
77°C - 85°C immediately.
8
. Touch to lighting the Continues Water icon. Then you can
take cold Cold/Ambient/ Sparkling water by one touch in-
stead of long press.
hinweise:
Safety
precautions
Product
introduction
W
orking
principle
USE Guide & maintenance
Using the product
trouble-