background image

MODEL  097

R

 

 

    OPERATOR'S
 

INSTRUCTIONS

(for USA & Canada)

 

 

WARNING

 

 

This X-ray unit may be dangerous to patient and operator unless 

safe  exposure  factors,  operating  instructions  and  maintenance 

schedules are observed.

 

DENTAL X-RAY

Содержание BELRAY II 097

Страница 1: ...R OPERATOR S INSTRUCTIONS for USA Canada WARNING This X ray unit may be dangerous to patient and operator unless safe exposure factors operating instructions and maintenance schedules are observed DEN...

Страница 2: ...F CONTROLS 4 4 OPERATING PROCEDURES 7 5 ESTIMATED AIR KERMA 7 6 OPTIONAL HAND EXPOSURE SWITCH 7 7 DIGITAL IMAGING SYSTEM 8 8 DISINFECTION AND CLEANING 8 9 ERROR CODES 9 10 MAINTENANCE 10 11 DISPOSAL 1...

Страница 3: ...housing assembly 097 H b X ray controls 097 CM main controller 097 CS sub controller c Cones 097 R regular 097 L long d Balance arm 097 A 4 COMPLIANCE WITH STANDARD The BELMONT BELRAY II MODEL 097 x r...

Страница 4: ...re warning light be at least 2 m away from the x ray head and patient and out of the path of the x ray beam or be positioned behind a protective device fully use all radiation protection devices acces...

Страница 5: ...justing Switch Down 12 Digital Imaging Switch 4 ExposureTimeAdjusting Switch Up 13 4 mA Selction Switch 5 Tooth Selection Switch T1 6 Tooth Selection Switch T2 7 Tooth Selection Switch T3 8 Tooth Sele...

Страница 6: ...I 0DQGLEOH 7 QFLVRU RI 0D LOOD XVSLG 3UHPRODU RI 0DQGLEOH 7 XVSLG 3UHPRODU RI 0D LOOD 0RODUV RI 0DQGLEOH LWHZLQJ 7 0RODU RI 0D LOOD LWHZLQJ 0RODUV 7 2FFOXVDO I WKH 7 VZLWFK LV GHSUHVVHG PRUH WKDQ VHF...

Страница 7: ...PRPHQWDULO GLVSOD V WKH VSHHG EHLQJ VHOHFWHG LQ WKH SRVXUH 7LPH LVSOD LQGRZ LWK WKH IDFWRU VSHHG VHWWLQJ G 08 WKH H SRVXUH WLPH EHFRPHV KDOI RI 08 VHWWLQJ As the sensitivity is different according to...

Страница 8: ...osure and an error code E 00 will be displayed in Exposure Time Display Window 16 6 switch once after setting to child If the weight of child is over 30kg and less than 50kg press Speed Setting mA Chi...

Страница 9: ...6ZLWFK in RUGHU WR SUHYHQW DFFLGHQWDO exposures when the unit is not in XVH 127 I WKH XQLW OHIW RYHU PLQ ZLWKRXW EHLQJ RSHUDWHG DQG WKH 0DLQ 3RZHU 6ZLWFK LV NHSW RQ ILJXUH UXQV WKURXJK WKH SRVXUH 7LPH...

Страница 10: ...QLQJ RI WKH SDUWV WKDW PD FRPH LQ FRQWDFW ZLWK VNLQ SHULRGLF GLVLQIHFWLRQ ZLWK D QRQ FRUURVLYH VXUIDFH GLVLQIHFWDQW LV UHFRPPHQGHG 5HFRPPHQGHG GLVLQIHFWDQW XUU HQWDO 237 0 7 6FL DQ WG U LQJ OORZ VXUID...

Страница 11: ...Malfunction of the microcomputer Tube current is detected during pre heating period Tube current is detected when main power switch is turned on Exposure switch or exposure circuit had been ON when ma...

Страница 12: ...ed service technician The specific instructions to perform these checks are located within the BELRAY II MODEL 097 Installation Manual A Line voltage confirmation B Tube current confirmation C Inspect...

Страница 13: ...long cone 1 9 3 3 mGy sec 40 Data obtained by direct measurement in the useful beam 16 Nominal electrical output of H V Generator 0 36kW at 70kVp 7mA 17 Cone Source to skin distance Field size a Regu...

Страница 14: ...netic emissions Emissions test Test procedure Compliance Note The emissions characteristics of this equipment make it suitable for use in industrial areas and hospitals CISPR 11 class A If it is used...

Страница 15: ...ding cables specified by the manufacturer Otherwise degradation of the performance of this equipment could result Radiated RF IEC61000 4 3 80 MHz 2700 MHz 3V m unmodulated r m s 80 AM 1kHz 80 MHz 2700...

Страница 16: ...w Jersey 08873 U S A TEL 732 469 5000 800 223 1192 Fax 732 526 6322 800 280 7504 www belmontequip com TAKARA COMPANY CANADA LTD 2455 Meadowvale Boulevard Mississauga Ontario L5N 5S2 Canada TEL 905 816...

Отзывы: