gas specification
Model No.
Gas type &
pressure
Electrical
power
Heat input and orifice size marked(mm)
Total Heat input
Rapid burner
Semi-rapid
Auxiliary- rapid
50Hz-60Hz
/
6.3 MJ/h
3.6 MJ/h
29.16 MJ/h
2.75kPa
/
0.68
0.53
NA
Natural Gas
1.0kPa
/
1.12
0.83
LPG
B DGM604/B DGM604-F
Work burner
12.96 MJ/h
0.97
1.60
220-240V~
Where a flexible hose assembly is used, ensure it is approved to
AS/NZS 1869, Class B. Any hose assembly used must be restrained
from accidental contact with the flue outlet of an under bench oven.
This hose assembly shall be suitable for connection to a fixed
consumer piping outlet located as follows:
Hotplates at a point 800 mm to 850 mm above the floor and in the
region outside the width of the appliance to a distance of 250 mm.
After connecting to gas, check for leaks using soapy solution, never a
naked flame.
Inlet connection region for flexible hose
Gas Connection
Install in accordance with relevant gas standards and/or codes of practice
applicable.
Connect the elbow fitting to the appliance gas manifold connection, and check
that seals between the elbow and manifold connection are in place and in good
condition.
For Natural gas: connect the natural gas appliance regulator (pictured
opposite) with integral test point using approved gas thread tape or
compound to the elbow fitting.
For Universal LPG: connect the brass test point adaptor (pictured opposite)
using approved gas thread tape or compound to the elbow fitting.
Ensure the supply connection point, test point and natural gas regulator
adjustment screw (for Natural gas installation) are accessible for testing and/or
adjustment with the hotplate in the installed position.
20