bell
swipe
Card Access System
System features
Ž
Up to 500 User cards.
Ž
Two Time Zones for Staff / Executive operation.
Ž
Outputs for Fail-safe and Fail-secure locks plus one isolated contact
Ž
Shadow cards for easy deletion of User cards
Ž
Eight function cards for easy system programming.
Ž
Hi-Co Cards for a long durable life: Secure encrypted card data.
Ž
Separate Control unit for maximum security.
Ž
Combined Power Supply and Control Unit for simplified installation.
Ž
Card data is retained after power failure using EEPROM.
Ž
Optional battery backup for operation during mains power failure.
BS500 Kit Components
1
CR500 Control Unit with integral Power Supply
1
RH10 Card Reader
1
203 Lock Release (fail-secure)
1
BSF Starter Pack of cards ( 8 Function cards + 16 user cards & shadow cards)
Optional Components
Part No.
Description
BS20C
Additional pack of cards for 20 users (includes shadow cards)
TS2000
Time Clock, 7 day, quartz reserve, 12V operated
BAT02
12V 2AH Battery for CR500
bell
swipe
Card Access System
Contents
General Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Basic Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Time-restricted access (Staff / Executive operation) . . . . . . . . . . . . . . 2
Exit Facility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Integrated Power Supply with optional battery backup . . . . . . . . . . . . 2
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Wiring diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Cable Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Important Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
CR500 Control Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
RH10 Card Reader . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Electric Lock Release . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Isolated Lock Relay Contact . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
High Current Lock Releases . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Time Restricted Access . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Exit Facility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Commissioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
BS500 Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Adding further User cards . . . . . . . . . . . . . . . . . . . . . . . . . . . 17