background image

4

 ADMINISTRATOR GUIDE

Please read the following User Guidance & Precautions before using the product:

1. 

As the product powers-up it performs a self-
test procedure. In case of a self-test failure, 
including jammed buttons, the product will be 
Inoperable. A Self-test failure will be indicated 
by the following LED behavior:

a. 

Unit’s anti-tamper mechanism has been activated:

Unit will rapidly and continuously switch channels

b. 

Jammed button or other failure to boot: Unit will 
slowly switch between channels.

To exit a self-test failure state, power cycle the 
unit. If the problem persists, contact your system 
administrator or Belkin technical support.

2. 

Product power-up and Reset to Factory Defaults:

a. 

By default, after product power-up, the active 
channel will be computer #1, indicated by the 
applicable front panel button LED being lit.

b. 

Product restore to factory defaults (RFD) function 
is available by pressing the following keyboard key 
sequence: Left CTRL | Left CTRL | f11 | r.

c. 

RFD action will be indicated by a single click

d. 

When the product reboots after RFD, the console 
keyboard and mouse will be mapped to the active 
channel #1 and default settings will be restored, 
erasing all user-set definitions.

3. 

The appropriate usage of peripherals (e.g. 

keyboard, mouse, display, authentication 
device) is described in detail in the User 
Manual’s appropriate sections. Do not 
connect any authentication device with an 
external power source to the product.

4. 

For security reasons and per NIAP 
and Common Criteria environmental 
requirements, product should never be used 
with wireless keyboards and mice.

5. 

For security reasons and per NIAP and Common 
Criteria environmental requirements, products 
should never be connected to a microphone 
input. Do not connect a microphone to the 
product audio output port, including headsets 
with microphone inputs. The KVM is designed to 
prevent audio input signal flow.

6. 

The Product is equipped with always-on active 
anti- tampering system. Any attempt to open 
the enclosure will activate the anti-tamper 
trigger, indicated by all channel- select LEDs 
flashing rapidly from one channel to the other. 
In this case, product will be inoperable. If the 
product’s anti-tamper evidence tape appears 
disrupted or if all channel-select LEDs flash 
continuously, remove product from service 
immediately and contact technical support.

User Guidance & Precautions

Important: For change management tracking, it is advised to perform a quarterly log check to verify that administrator 
accounts and log on events can be verified.

Содержание Secure KVM - NIAP PP4.0

Страница 1: ...Belkin Administrator Guide Products covered by this guide Belkin Secure KVM NIAP PP4 0 LNKPG 00666 Rev B00 ...

Страница 2: ...ntroduction 1 Intended Audience 1 Revision History 1 Safety Precautions 2 Safety Precautions French 3 User Guidance Precautions 4 Administrator Configuration 6 Terminal Mode Operation 8 Table of Contents ...

Страница 3: ...amper evident security tape that will provide visual indication of attempts to open the enclosure Further the product is equipped with an always on active anti tamper mechanism Any attempt to open the enclosure will activate the anti tamper trigger and render the unit permanently inoperable If the product s anti tamper security tape appears disrupted or if all the channel LEDs flash continuously d...

Страница 4: ...working well even after carefully following the instructions in this administrator s manual The product has been dropped or is physically damaged The product shows obvious signs of breakage or loose internal parts In case of external power supply If power supply overheats is broken or damaged or has a damaged cable The product should be stored and used only in temperature and humidity controlled e...

Страница 5: ...t faites vérifier l appareil par un technicien de maintenance qualifié En cas d alimentation externe L alimentation de l appareil surchauffe est endommagée cassée ou dégage de la fumée ou provoque des court circuits de la prise du secteur Un liquide a pénétré dans le boîtier de l appareil L appareil est exposé à de l humidité excessive ou à l eau L appareil ne fonctionne pas correctement même aprè...

Страница 6: ...gs will be restored erasing all user set definitions 3 The appropriate usage of peripherals e g keyboard mouse display authentication device is described in detail in the User Manual s appropriate sections Do not connect any authentication device with an external power source to the product 4 For security reasons and per NIAP and Common Criteria environmental requirements product should never be u...

Страница 7: ...labeled remote This port can be used with various remote controls and if connected the operation must be verified and secured 10 Important After re allocating computers to channels it is mandatory to power cycle the product keeping it powered OFF for more than 1 minute 11 The product log access and administrator configuration options are described starting in the next section 12 Administrator auth...

Страница 8: ...r name Once a new Admin user has been created there is no way to reset or delete that user Important note before deploying the product To comply with the product s Common Criteria requirements and to prevent unauthorized administrative access the default administrator password must be changed prior to first use Caution The KVM device must be installed in an environment that provides physical secur...

Страница 9: ... default password The new password must be at least a 8 characters long but not longer than 24 characters b Have at least one capital and one lower case letter c Have at least one number d Have at least one symbol 8 Password must be typed twice to confirm 9 Password may be changed at any time 10 RFD will not reset the user name and password 11 If the user name or password is forgotten contact Belk...

Страница 10: ...ents 7 configure peripheral devices 8 back 9 exit terminal mode 10 power cycle the KVM Select any of the options by typing the number on the keyboard Make sure NOT to use the keyboard s numeric pad it does not work Only the main keyboard numbers work NOTE To get out of Admin mode type 8 as seen in the menu above or power cycle the KVM switch As long as the unit is in Admin mode keystrokes are not ...

Страница 11: ...d change the devices that are allowed through the DPP dedicated peripheral port This is the CAC port By default all authentication devices and only authentication devices are allowed You can also use a tool that gives you for more functionality The options are 1 allow currently connected device on all channels 2 block currently connected device on all channels 3 show currently connected device 4 s...

Страница 12: ...a color Please select operation l Blue 2 Red 3 Green 4 Yellow 5 Purple 8 Back 9 Exit terminal mode 4 Account Management Manage add and remove administrator accounts The options are 1 change password 2 create admin account 3 delete all accounts 8 back 9 exit terminal mode Up to nine additional administrator accounts may be created The additional accounts can be removed or renamed by the admin and w...

Страница 13: ... stores up to 100 latest events and deletes the oldest ones when it is full The Non Critical RAM log Its information is never deleted not even during the RFD The events kept on this log are events like power up peripheral device acceptance simple configuration change Admin logon user add delete password change or password lock and so on The RAM log stores up to 128 latest events and deletes the ol...

Страница 14: ... enclosure Further the product is equipped with an always on active anti tamper mechanism Any attempt to open the enclosure will activate the anti tamper trigger and render the unit permanently inoperable If the product s anti tamper security tape appears disrupted or if all the channel LEDs flash continuously do not install the unit and call Belkin Technical support at 1 800 282 2355 ...

Страница 15: ...LNKPG 00666 Rev B00 ...