background image

 

 

 

 

21

 

ePowerSwitch Configuration 

Each outlet can be individually programmed to enable ring 
On/Off or reset.   Power resume delay is convenient for 
sequential startup.  Name of each outlet can be labeled to 
whatever you like it to be called. For example, server1, DSL 
modem, webserver1, etc.  Since 16 ePowerSwitches can be 
daisy chained together to share one NIC, so each unit can be 
individually named.  The last item “Enable waiting device 
shutdown” is dedicated to Microsoft Windows NT (4 and 
2000, workstation and server) to have a safe shutdown. If you 
installed an optional NT card inside the ePowerSwitch, there is 
a delay time for the corresponding outlet of the NT card to off 
the power for the safe shutdown functionality. The default delay 
time is set up as 5 minutes.  

 

 

Содержание ePowerSwitch F1D001

Страница 1: ...User Manual ePowerSwitch By BELKIN 34000179 19 Sep 02 Copyright 2000...

Страница 2: ...tion Conventions Used In This Guide This guide uses these conventions Bold italic print as shown in this example indicates field names menu items or values in the ePowerSwitch software agent Bold prin...

Страница 3: ...gateway and subnet 7 2 Setup via serial port 8 Serial or Telnet Configuration 11 Use terminal to set IP gateway and subnet 11 3 Setup via USB port 13 4 Telnet Options 15 5 Setup via Ethernet Cascaded...

Страница 4: ...ii ii Telephone access interface 27 Appendix 30 Reference 30 Communities 30 IP Addresses 30 Subnetting and Subnet Masks 31 Gateways 33 Glossary 34 Troubleshooting 36...

Страница 5: ...ocked up devices or servers Sequentially apply power to equipment that is plugged into the ePowerSwitch Multiple OS support As long as there is Network Management software present Remote setup support...

Страница 6: ...ON OFF status for each of the rear output socket respectively from A to H Green LED indicates the Internet remote control or non Internet front panel control status of the corresponding socket You ma...

Страница 7: ...tch there is a delay time for the corresponding outlet of the NT card to off the power for the safe shutdown functionality The default delay time is set up as 3 minutes RJ 11 Jacks iLink Port Daisy ch...

Страница 8: ...iskette User Manual NIC Web Card w USB Cable RS232 Cable Phone Card NT Card w PC Communication Cable ePowerSwitch iLink Cable for Daisy Chain UPS iLink Cable The ePowerSwitch System Unit Figure 1 show...

Страница 9: ...floppy Users are encouraged to use USB setup Requires English version of Windows 98 either first or second edition Serial Port The serial port on the front is designed for initial setup of the card Nu...

Страница 10: ...RS232 port using terminal software e g Windows HyperTerminal 3 Setup via USB port using ePowerSwitch USBSetup software USBSetup software included 4 Setup IP address by using ARP command first time on...

Страница 11: ...setup IP address only for the first time and the IP address is temporarily 3 Use a Web browserto enter in and configure all ePowerSwitch network parameters with the IP address you setup by ARP command...

Страница 12: ...ia serial port Before setup you need 1 IP address Get a valid IP address from administrator 2 RS232 Cable enclose 3 Dumb terminal software ex HyperTerminal in the win95 98 NT Win2000 4 Default passwor...

Страница 13: ...connecting the ePowerSwitch System through the serial port 1 Connect the RS232 port to a dumb terminal PC with RS232 cable 2 Setup terminalsoftware 1 Open terminal software select Property in File ca...

Страница 14: ...ow configured to communicate with the ePowerSwitch 4 Approximately three seconds after you turn on AC power the terminaldisplays Check u dram Within 5 seconds press when you see Waiting five seconds t...

Страница 15: ...Web Card starts up Approximately three seconds after you turn on the power for ePowerSwitch the NIC card displays Check u dram Press when you see Waiting five seconds to enter console configuration Yo...

Страница 16: ...nimum requirement to operate ePowerSwitch Systemis to set the IP address If you want to return to the Main Menu press Esc key For more information on IP addresses and net masks see the Reference secti...

Страница 17: ...nd USBSetup file Enclose in the disk 1 Connect the ePowerSwitch to a Windows 98 PC through an USB cable If the PC prompts for a new driver insert the floppy provided Uncheck update Windows 98 check bo...

Страница 18: ...14 to see the device because the ePowerSwitch takes about 30 seconds to boot 2 The USB interface power device name must appear in the System Properties dialog box before you run the USB setup softwar...

Страница 19: ...evice See the following figure You need to run Device Update Restart before closing 4 Telnet Options You can also Telnet to the IP address of the ePowerSwitch System after it has been installed on you...

Страница 20: ...er information locally in order to successfully make a Telnet connection 5 Setup via Ethernet Cascaded Cable Before setup you need 1 IP address Get a valid IP address from administrator 2 Ethernet Cas...

Страница 21: ...n is useful if it is not possible to make a direct network connection to the ePowerSwitch Again the external modem is needed to connect to the front serial port of the NIC Web card of the ePowerSwitch...

Страница 22: ...e PPP configuration ePowerSwitch will then automatically dial up to the designated ISP and send the e mail to the designated e mail address with the assigned IP address from ISP 3 User may browse and...

Страница 23: ...19 User Management Administrators canassign the maximum of4 users to control the outlet...

Страница 24: ...20 20 Software Update This is the place you can upgrade the firmware when it is available or bug fix...

Страница 25: ...Since 16 ePowerSwitches can be daisy chained together to share one NIC so each unit can be individually named The last item Enable waiting device shutdown is dedicated to Microsoft Windows NT 4 and 2...

Страница 26: ...ommunication port on the rear of ePowerSwitch to NT or WIN 2000 server with the PC Communication cable Connect the corresponding outlet on the rear of ePowerSwitch to the NT or WIN 2000 server with th...

Страница 27: ...23 Scheduled shutdown Scheduled shutdown can be accomplished here Be careful with which outlet you are working...

Страница 28: ...NMS Network Management Station a If you do not get a response check the card s network connection and IP address 3 Test the adapter with an NMS Perform a get and a set a If the get or set commands fa...

Страница 29: ...lt directory of the TFTP server RS232 Serial Port Console Upgrade The following steps guide you in connecting the ePowerSwitch System through the serial port 1 Connect the RS232 port to a dumb termina...

Страница 30: ...26 26 the user data are lost...

Страница 31: ...e default password is 123456789 4 The ePowerSwitch will send out a 3 short beep to confirm successful login b A long beep to deny access 5 Once logged in remote user can change ID Address 333XXxx is C...

Страница 32: ...rSwitch02 outlet H on after 3600 minutes 02803600 means turn ePowerSwitch02 outlet H off after 3600 minutes 02823600 means reset ePowerSwitch02 outlet H after 3600 minutes Use combination of 0111XXXX...

Страница 33: ...what and user input 888XXXXXXXXXX the second time to re confirm and ePowerSwitch acknowledge 4 short beeps indicating password change completed 10 Hang up to close access 11 Each command string shoul...

Страница 34: ...so that only trap managers that are members of a community can send requests and receive responses from a particular community This prevents unauthorized managers from viewing or changing the configur...

Страница 35: ...ID Host ID Number of Hosts A 1 126 first octet last three octets 16 387 064 B 128 191 first two octets last two octets 64 516 C 192 223 first three octets last octet 254 Any value between 0 and 255 is...

Страница 36: ...he host ID For the example above if you want all the devices on the subnetworks to receive each other s IP packets set the subnet mask to 255 255 0 0 If you want the devices on a single subnetwork onl...

Страница 37: ...s Gateways Gateway also referred to as a router is any computer with two or more network adapters connecting to different physical networks Gateways allow for transmission of IP packets among networks...

Страница 38: ...access the network at the same time LAN hardware manufactures use EtherNet protocol their products may not be compatible Gateway A computer that attaches to a number of networks and routes packets bet...

Страница 39: ...nt A software module that manages specific MIB sub groups for an Agent They communicate with the Agent using a SMUX multiplexer TCP IP Transmission Control Protocol Internet Protocol A protocol suite...

Страница 40: ...a bits and 1 stop bit The cable is a null serial cable PROBLEM The NMS cannot ping the ePowerSwitch System Solution Make sure the network connection to the ePowerSwitch System is good Solution Make su...