background image

23

Electric  shock  protection  type  :Class  II  

equipment 

Disposal in accordance with Directive 2002/96/

EC (WEEE)

Complies  with  the  European  Medical  Device 

Directive  (93/42/EEC),  Notified  Body  is  SGS 

Belgium NV

Manufacturer: Famidoc Technology Co. , Ltd

Authorized  representative  in  the  European 

Community

Serial number

Temperature limitation

Humidity limitation

Atmospheric pressure limitation

IP22

Level of protection for ingress of water or 

particulate matter into ME EQUIPMENT

13. Electromagnetic compatibility 

13. Electromagnetic compatibility 

information

information

Note:

• 

Important information regarding Electro Magnetic Com-

patibility (EMC). 

• With the increasing number of electronic devices such as 

PC's and mobile (cellular) telephones, medical devices in 

use may be susceptible to electromagnetic interference 

from other devices. Electromagnetic interference may re-

sult in incorrect operation of the medical device and create 

Содержание FDES115

Страница 1: ...ons in this Manual book are effect drawings please refer to the real object Thanks for using our product Take good care of this instruction Precaution Please read the instructions carefully before use...

Страница 2: ......

Страница 3: ...t structure description 5 5 Product description 8 6 Treatment procedures 11 7 Operation 12 8 After the treatment is completed 16 9 Troubleshooting 20 10 Product specifications 21 11 Final disposal 22...

Страница 4: ...siological reactions and finally affects the pathological process and plays a corresponding role Customer service Customer service support belifu com Please download the manual on below link https bel...

Страница 5: ...ain from exercise or normal household work activities For EMS mode To be used to stimulate healthy muscles in order to improve and facilitate muscle performance For MASSAGE mode To be used for recover...

Страница 6: ...ot use this device if the patient has any implantable electronic or metal equipment e g pacemaker 2 Has epilepsy 3 Severe lower extremity arterial circulation problems 4 Abdominal or inguinal hernia s...

Страница 7: ...ng Note Note 1 Electrode pad is too long may cause suffocation Keep the product and keep away from children 2 Make sure you are always aware of all warning items 3 Stimulators should not be used in th...

Страница 8: ...or malignant mass Patients with various skin diseases Patients with chronic pain disorders e g metabolic disorders with reduced pain Patients undergoing medication Adverse reaction Adverse reaction Sk...

Страница 9: ...en the electrode pad is stuck to the clothes don t tear it off heavily As long as the inside of the side with the electrode pad is covered with water it can be removed easily 5 2 TENS 5 2 TENS MASS EM...

Страница 10: ...der may be stiff and painful due to long term of movement and weight bearing Stick the electrodes to the cervical spine Stick the electrodes to the shoulder 2 Lower back there are many possible causes...

Страница 11: ...l kinds of acute and chronic pain intractable pain or pain caused by daily work related activities Promote blood circulation and eliminate fatigue Suitable for strengthening muscle preventing muscle a...

Страница 12: ...uctivity and has very good thermal conductivity The heating temperature of the product has 3 levels E1 Low temperature 95 35 E2 Medium temperature 98 6 37 E3 High temperature 102 2 39 7 Operation 7 Op...

Страница 13: ...eatment mode of the CD channel 5 Press the button to select the treatment program of the CD channel 6 Adjust the heat function Long press the button for 3 seconds to enter the heat mode In the heat mo...

Страница 14: ...tment intensity level The maximum intensity is 40 Press the A or D to increase the intensity by 1 level of AB channel or CD channel The machine will start working once the intensity is higher than 0 P...

Страница 15: ...Mode icons will flicker press to suspend treatment when changing the massage points and press again to continue the treatment Only in the locked state can the treatment be paused 10 If the time needs...

Страница 16: ...TENS EMS MASSAGE UNIT can be cleaned but you cannot clean the gel Cleaning the electrode pad Cleaning the electrode pad 1 Remove the gel and discard before cleaning the pad 2 When the pad have become...

Страница 17: ...h temperature humidity direct sunlight Do not wipe dirts on pads with thinner gasoline etc During maintenance please handle the electrodes carefully Not bendable Do not force or drag Do not touch wate...

Страница 18: ...300 IM 3 3 6 6 30 50 300 IM 2 2 4 4 30 75 300 IM 3 3 6 10 30 50 200 IM 2 2 4 4 30 50 200 IM 5 5 1 1 2 For TENS mode Program Name Time min Frequen cy Hz Pulse width uS Wave TENS 30 2 180 Con 30 80 2 1...

Страница 19: ...e Pro Name Time min Frequen cy Hz Pulse width uS Ramp up and ramp down time s Keep Time s Release Time s 30 3 300 0 0 Con 0 30 33 80 300 6 6 0 0 30 25 150 280 6 6 0 0 30 8 80 0 0 Con 0 30 3 8 80 0 0 7...

Страница 20: ...purchased from Belifu official store or contact support belifu com Unit does not turn on or the screen is dim Battery is low Recharge the battery Does not provide adequate pain relief Not using it lo...

Страница 21: ...er the locked state after 30 seconds of inactivity then you can press the to suspend the treatment 10 Product specifications 10 Product specifications Product name HEAT TENS EMS MASSAGE UNIT Model FDE...

Страница 22: ...ctric shock II equipment Applied part BF Application Section Electrode pad is type BF applied part Grade of waterproof IP22 Accessories HEAT TENS EMS MASSAGE UNIT Electrode pad Type C data cable Manua...

Страница 23: ...eric pressure limitation IP22 Level of protection for ingress of water or particulate matter into ME EQUIPMENT 13 Electromagnetic compatibility 13 Electromagnetic compatibility information information...

Страница 24: ...s equipment adjacent to or stacked with other equipment should be avoided because it could result in improper operation If such use is necessary this equipment and the other equipment should be observ...

Страница 25: ...or the user of the FDES115 should assure that it is used in such an environment Immunity test IEC 60601 test level Compli ance level Electromagnetic envi ronment guidance Electrostat ic discharge ESD...

Страница 26: ...5 be powered from an uninterrupt ible power supply or a battery Power frequency 50 60 Hz magnetic field IEC 61000 4 8 30A m 30A m Power frequency magnetic fields should be at levels characteristic of...

Страница 27: ...IEC 60601 1 2 2014 Portable and mobile RF communications equipment should be used no closer to any part of the FDES115 including cables than the recommended separation distance calculated from the eq...

Страница 28: ...n 0 15 MHz and 80 MHz are 1 8 MHz to 2 0 MHz 3 5 MHz to 4 0 MHz 5 3 MHz to 5 4 MHz 7 MHz to 7 3 MHz 10 1 MHz to 10 15 MHz 14 MHz to 14 2 MHz 18 07 MHz to 18 17 MHz 21 0 MHz to 21 4 MHz 24 89 MHz to 24...

Страница 29: ...gnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment transmitters and the FDES115 as recommended below according to the maximum output power of...

Страница 30: ...ference in a residential installation This device generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference...

Страница 31: ...All damage which has arisen due to improper treatment e g nonobservance of the user instruction All damage which is due to repairs or tampering by the customer or unauthorized third parities Damage wh...

Страница 32: ...ogy Co Ltd Add No 212 Yilong Road Hexi Industrial Zone Jinxia Changan Town Donguang 523853 Guangdong Province P R China Name Shanghai International Holding Corp GmbH Europe Add Eiffestrasse 80 20537 H...