14

Setting Up Your Multiviewer

Using the Kaleido-RCP2 with Default Settings

To start using the Kaleido-RCP2 with its default settings

1 Physically connect the Kaleido-RCP2 unit to the network using an Ethernet cable (see 

Cabling Diagram

, on page 8).

By default, the Kaleido-RCP2 is configured with DHCP enabled, so it will automatically 
be assigned an IP address by a DHCP server. If no DHCP server can be found, the 
Kaleido-RCP2 will fall back to its default static IP address, subnet mask, and gateway 
settings:

2 On the Kaleido-RCP2 unit, press the ENTER button and hold it until the ESC button 

lights up.

The following message appears on the LCD display:

 

Configuration

 

ROOM SELECTION

 

3 Press ENTER again to obtain the room list from the multiviewers that are currently 

available on the network.

The message 

ROOM Select

 followed by the name of the first room available appears on 

the LCD display.

4 Press  the 

2

 key (to move up in the list) or the 

8

 key (to move down the list) until 

Room1

 

is displayed.

5 Press ENTER, and then press ESC to exit the configuration menu.

6 Press the LOGIN button.

The following message appears on the LCD display:

LOGIN Position

 

Admin

 

7 Press ENTER to log on to your system as “Admin”.

A message prompting you for a password appears on the LCD display.

8 Press ENTER again (by default, there is no password).

Default IP address

10.0.3.191

Default subnet mask

255.255.0.0

Default gateway

0.0.0.0

Notes 

• If you need to operate with a fixed IP address, you must use the 

Configuration menu to disable DHCP and set up the correct IP address, 
Network Mask, and Gateway (see the “Enabling or Disabling DHCP” and 
“Setting an IP Address, Subnet Mask and Gateway” sections in the 

Kaleido-

RCP2 Guide to Installation and Operation

, available on the DVD that shipped 

with your system.)

• To access rooms located in other subnets, the Kaleido-RCP2 must be 

configured with the appropriate unicast IP addresses (see the “Configuring 
Unicast IP Addresses” section in the 

Kaleido-RCP2 Guide to Installation and 

Operation

, available on the DVD that shipped with your system.)

Содержание Miranda KMV-3901

Страница 1: ...Quick Start Guide M866 9905 109 12 January 2014...

Страница 2: ...on and license to owners of Kaleido multiviewers to use their product manuals for their own internal business use Manuals for Miranda products may not be reproduced or transmitted in any form or by an...

Страница 3: ...Surge transient immunity EN 61000 4 6 Conducted disturbances immunity EN 61000 4 8 Power frequency magnetic field immunity EN 61000 4 11 Voltage dips short interruptions and voltage variations immunit...

Страница 4: ......

Страница 5: ...e KMV 3901 3911 cards can be configured into a single or dual output system supporting up to 24 inputs At the heart of every multiviewer system is the Kaleido X software which includes two client appl...

Страница 6: ...3911 or KMV 3901 card front and rear modules One or two 35 cm 14 inch DIN to BNC cable adapters for KMV 3911 models with HD SDI monitoring output option only The KMV 3901 3911 Quick Start Guide this...

Страница 7: ...s On all Miranda multiviewers the network adapters are set to auto negotiate By default the connection speed and duplex mode will be set automatically based on the corresponding port settings on the s...

Страница 8: ...roller Card with firmware version 2 0 4 or later A controller with an earlier version of the firmware cannot provide a time reference to the multiviewer card Make sure the controller s internal clock...

Страница 9: ...eo inputs are green Notes The Kaleido RCP2 is an optional device and may not have been shipped with your KMV 3901 3911 system For information on this and other options for your multiviewer system plea...

Страница 10: ...red with the same refresh rate If your frame is referenced then the heads refresh rate must also match the reference signal s refresh rate Note You can navigate the control menu by using the four butt...

Страница 11: ...button HEAD 2 appears on the LCD display and you can repeat step 4 to step 8 above to verify or configure the resolution of the display that is connected to the multiviewer s output head 2 i e through...

Страница 12: ...rds it will not be necessary to switch off the Densit frame s power when installing or removing cards IMPORTANT If you need to install or momentarily remove a Densit card s rear module make sure to fi...

Страница 13: ...on if needed 1 On the Densit frame s local control panel press the CONTROLLER button 2 Press the button repeatedly until RESTORE POINTS appears on the display and then press the SEL button 3 Press the...

Страница 14: ...e the current value at the current input position Press SEL to move one position to the right Note You can navigate the control menu by using the four buttons located beneath the display Press the and...

Страница 15: ...tely five minutes during which time the Status LED is blinking orange Once the startup has completed the Status LED should be red steady because the card is not connected to the network yet 11 Connect...

Страница 16: ...the SEL button 16 Press the button repeatedly until SAVE A CARD appears on the display and then press the SEL button 17 Press the button repeatedly until CARD N where N matches the slot number for th...

Страница 17: ...card e g 5 00 build 21 appears on the display 3 On the local control panel press the button repeatedly until NETWORK SETTINGS appears on the display and then press the SEL button IP ADDRESS EDIT appea...

Страница 18: ...in the list or the 8 key to move down the list until Room1 is displayed 5 Press ENTER and then press ESC to exit the configuration menu 6 Press the LOGIN button The following message appears on the LC...

Страница 19: ...lternatively connect the mouse directly to the USB port at the front of the KMV 3901 3911 card 2 Right click anywhere on the monitor wall point to Monitor wall if you clicked a monitor and then click...

Страница 20: ...In Network Connections right click Local Area Connection and then click Properties If the system prompts you for an administrator password or confirmation type the password or provide confirmation Th...

Страница 21: ...and then click Open on the shortcut menu 2 In Network Connections right click Local Area Connection and then click Properties on the shortcut menu 3 In Local Area connection Properties select Interne...

Страница 22: ...et as the multiviewer open a Web browser window and type the multiviewer s IP address in the address bar The Kaleido X home page appears 2 Click the XEdit button The browser prompts you to save an exe...

Страница 23: ...indow appears showing the download and installation progress At the end of the installation process launcher icons are added to your desktop and to the Start menu under All Programs Once the installat...

Страница 24: ...r automatically in which case a message will appear to confirm the font update and instruct you to restart the application Click OK to continue and then open XEdit again by using the launcher icon on...

Страница 25: ...ped with your system and from Miranda s support portal Note Once it has been installed from the multiviewer XEdit remains on your PC or laptop and can be launched from the icon that was added to your...

Страница 26: ......

Страница 27: ...514 335 1614 E mail support miranda com Asia Office hours 9 00 a m 5 00 p m GMT 8 Telephone 852 2539 6987 Fax 852 2539 0804 E mail asiatech miranda com Europe Middle East Africa UK Office hours 9 00...

Отзывы: