Power supply
Type N
Rated voltage range DC
72 V ... 110 V
Voltage range DC incl. maximum
tolerances
50.4 V ... 138 V
Connection type
7/8" connectors, 4-pin
Tightening torque
22 lb-in
(2.5 Nm)
Power loss buffer
> 10 ms
No buffering of powered devices
(PDs)
Overload current protection at input Non-replaceable fuse
Back-up fuse
Nominal rating:
Characteristic:
2.5 A
slow blow
Peak inrush current
2.5 A
Insulation voltage between supply voltage connections
and housing
Supply voltage
Type A
707 V DC
Type F
707 V DC
Type N
1414 V DC
“FAULT”
signal contact
Switching current
max. 1 A, ohmic load
Switching voltage
max. 48 V DC, SELV
Connection type
M12 connector, 5-pin
Tightening torque
5.3 lb-in (0.6
Nm)
Climatic conditions
during operation
Ambient temperature
−
40 °F ... +158 °F
(
−
40 °C ... +70 °C)
a
Humidity
5 % ... 100 %
(also in condensing atmospheres)
b
Air pressure
minimum 795 hPa
(+6562 ft; +2000 m)
maximum 1060 hPa
(
−
1312 ft;
−
400 m)
Climatic conditions
during storage
Ambient temperature
−
40 °F ... +185 °F
(
−
40 °C ... +85 °C)
Humidity
5 % ... 100 %
(also in condensing atmospheres)
c
Air pressure
minimum 700 hPa
(+9842 ft; +3000 m)
maximum 1060 hPa
(
−
1312 ft;
−
400 m)
Degree of
protection
IP65/67
d
Mounting
Flat surface mounting
Screw type
M5
Pollution degree
2
a. Applies to devices with PoE only as long as the temperature of the device base plate remains
under 194 °F (90 °C).
b. Remove the provided transport protection caps and the transport protection screws from the
device. Seal unused sockets and plugs with your desired type of protection screws which
you can order separately.
c. Remove the provided transport protection caps and the transport protection screws from the
device. Seal unused sockets and plugs with your desired type of protection screws which
you can order separately.
d. To preserve the suitability of your device for IP65/67, proceed as follows: Remove all
provided transport protection caps and transport protection screws. Seal unused sockets
and plugs with your desired type of protection screws which you can order separately.
Содержание HIRSCHMANN OCTOPUS OS20 Series
Страница 45: ...Installation OCTOPUS OS20 OS24 Managed Release 10 08 2017 45 ...
Страница 46: ......