Installation OCTOPUS OS20/OS24 Managed
Release 10 08/2017
23
1.7
Management interfaces
1.7.1
V.24 interface (external management)
The V.24 interface is an M12 socket.
The V.24 user interface is serial and allows you to connect the following
devices directly:
External management station (VT100 terminal or PC with appropriate
terminal emulation). With this management station, the Command Line
Interface (CLI) is available to you. Furthermore, the system monitor is
available to you at the system start.
An AutoConfiguration Adapter ACA11
The socket housing is electrically connected to the housing of the device.
Applies to devices featuring supply voltage with the characteristic value A:
The V.24 interface is not electrically isolated from the supply voltage.
Figure 1: Pin assignment of the V.24 interface and the DE9 connector
The Terminal cable is available as an accessory.
You will find a description of the V.24 interface in the “User Manual Basic
Configuration” document.
VT 100 terminal settings
Speed
9600 Baud
Data
8 bit
Stopbit
1 bit
Handshake
off
Parity
none
Figure
Pin
Function
1
TX. Transmit
Data
2
RX Receive
Data
3
N.C. Not
used
4
GND
Ground
Table 5:
Pin assignment of the V.24 interface (M12 socket)
5
M12
M12
DB9
DB9
2
3
5
1
2
3
4
1
2
3
4
6
7
8
9