Installation OCTOPUS OS20/OS24 Managed
Release 10 08/2017
37
6
Technical data
General technical data
Dimensions
W × H × D
See “Dimension drawings” on page 39.
Weight
67.02 oz (1900 g)
Power supply
Type A
Redundant power supply
Note:
Ensure that the externally power unit connected upstream fulfills
one of following conditions:
NEC Class 2
Limited Power Source based on EN 60950-1
Rated voltage range DC
24 V ... 48 V
Observe the warning for
railway standard EN 50155!
See “Devices featuring supply
voltage with the characteristic
value A” on page 26.
Voltage range DC incl. maximum
tolerances
9.6 V DC ... 60 V DC
Connection type
M12 connector, 5-pin
Tightening torque
5.3 lb-in
(0.6 Nm)
Power loss buffer
> 10 ms
Overload current protection at input Non-replaceable fuse
Back-up fuse
Nominal rating:
Characteristic:
2 A
slow blow
Peak inrush current
14 A
Power supply
Type F
Redundant power supply
Rated voltage range DC
24 V ... 48 V
Observe the warning for
railway standard EN 50155!
See “Devices featuring supply
voltage with the characteristic
value F” on page 27.
Voltage range DC incl. maximum
tolerances
16.8 V ... 60 V
Connection type
7/8" connectors, 5-pin
Tightening torque
22 lb-in
(2.5 Nm)
Power loss buffer
> 10 ms
No buffering of powered devices
(PDs)
Overload current protection at input Non-replaceable fuse
Back-up fuse
Nominal rating:
Characteristic:
7 A
slow blow
Peak inrush current
4.9 A