insta-
KLEEN™ MANUAL
46
Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681
1MANUL334
Operation
insta-KL
EEN™ Control Center (ICC)
Operator Interface
Outputs
The outputs are 110VAC solid state up to 4 amps. Each output has its own fuse and module. The lights on controller
and on output module will light up when output is on. Make sure switches are in Auto position to operate wash.
OUTPUT O0: Roller-Up
–
Turns on when controller calls for Roller. Output will stay on until user selected number of
Rollers is counted. Activates solenoid on roller up air panel to raise conveyor Roller ramp.
OUTPUT O1: Conveyor
–
The output turns on when controller is calling for conveyor on. Output will remain on until
user selectable time has expired after wash no longer needs conveyor. Activates motor starter in panel for conveyor
hydraulic unit.
NOTE:
This Output will not function
in “AUTO” unles
s Input X7 is on.
OUTPUT O2: Titan
–
Output will come on a user selectable number of seconds after treadle signal. Once on it will
remain on for a user selectable period of time.
OUTPUT O3: Pre-Soak
–
Output will come on a user selectable number of seconds after treadle signal. Once on it
will remain on for a user selectable period of time.
OUTPUT O4: Zone 1 Equipment
–
Will be on as soon as vehicle runs over treadle. Will remain on as long as any
vehicles are between treadle and photo-eye. Will turn off af
ter 5 seconds when no vehicle’s presen
t.
OUTPUT O5: Zone 1 Water
–
Will come on when Pre-soak comes on. Will turn off if car is user selectable number
of seconds into the photo-eyes or it is through photo-eyes if it
’s the last car
in wash. Will turn off for same conditions,
if two cars in wash, but second car has not yet turned on pre-soak. Output
won’t
turn off if >=3 cars is in wash.
OUTPUT O6: Zone 2 Equipment
–
Will come on 3 second after Zone 1 equipment comes on. Will turn off at same
time as Zone 1 equipment.
OUTPUT O7: Zone 2 Water
–
Will come on a user selectable number of seconds after treadle signal. Will turn off if
car is through photo-eye and it is the last car in wash. Will turn off for same condition if two cars in wash but second
car has not yet turned its Zone 2 water on. Outpu
t won’t turn
off if >=3 cars is in wash. If system does not have Zone
2 use this valve to distribute solution to exit most equipment in tunnel.
OUTPUT O10: Zone 1 & 2 Soap
–
Will come on if either Zone 1 or Zone 2 water is on. Output may also be used to
pressurize reclaim water for Zone 1 and 2 if necessary.
OUTPUT O11: Rinse/Wax Arch
–
Will come on if one or more cars are in wash and one of them is blocking the
rinse arch photo-eye.
OUTPUT O12: Dryer
–
If M502 = OFF the dryer will come on when a vehicle is in wash and it breaks the rinse/wax
photo-eye. Dryer will turn off a user selectable number of seconds after the vehicle is
through
the photo-eye. If
M502= ON, the dryer will be on whenever a vehicle is in the wash. Dryer will turn off a user selectable number of
seconds after wash is clear of vehicles. Set to on if dryers not winding up before car gets through a short tunnel.
OUTPUT O13: Extra Function
–
this output will turn on when input X5 is off. It will turn off a user selectable number
of seconds after input is back on. Intended to control equipment before rinse/wax photo except when X2 tied to X5
and this equipment is immediately after rinse/wax arch.