insta-
KLEEN™ MANUAL
16
Belanger, Inc. * PO BOX 5470 * Northville, MI 48167-5470 * Ph (248) 349-7010 * Fax (248) 380-9681
1MANUL334
Specifications
Requirements
Utility
Electrical
–
Control
Control Power 115VAC\50-60hz\1phase\8A
Electrical
–
3phase
Base Unit: (3 motor Starter)
208VAC\60hz\3Phase\23.5A
230VAC\60hz\3Phase\22.1A
400VAC\50hz\3Phase\8.3A
460VAC\60hz\3Phase\10.2A
Deluxe Unit: (6 motor Starter)
208VAC\60hz\3Phase\41.95A
230VAC\60hz\3Phase\36.5A
400VAC\50Hz\3Phase\14.3A
460VAC\60hz\3Phase\18.25A
Pneumatic
3 HP air compressor (Customer Supplied) / 225kW air compressor (Customer Supplied)
90 PSI minimum 120 PSI maximum / 620kPa Minimum 827kPA Maximum
Water (fresh)
(1) 1” pipe @ 18 GPM @ 40 PSI fresh water
/ 25mm pipe @ 4m
3
/h @ 275kPa
Water
(Reclaim - if applicable)
(1) 1” pipe @ 18 GPM @ 40 PSI fresh wa
ter / 25mm pipe @ 4m
3
/h @ 275kPa
ICC space requirements
Dimensions
Unit height
36-1/2
“
/ 927mm
Unit width
42-
1/2”
/ 1080mm
Unit depth
10”
/ 254mm
NOTE:
BELANGER® RECOMMENDS THAT ARC FLASH ASSESSMENT IS PERFORMED
AFTER INSTALLED. THE ARC FLASH BOUNDARY LEVELS CANNOT BE
DETERMINED AT THE FACTORY.
Note:
Available in 3,4,5,6
& 7 Motor Starters.
Typical model
specs listed. Refer
to label on
enclosure for other
electrical specs.