![BelAir Networks BelAir 100SN Скачать руководство пользователя страница 132](http://html.mh-extra.com/html/belair-networks/belair-100sn/belair-100sn_user-manual_2725293132.webp)
BelAir100SN User Guide
Mobile Backhaul Point-to-point Links
May 31, 2010
Confidential
Document Number BDTM11001-A01 Released
This command let you configure this feature. If set to
false
, the BelAir100SN
maintain the link even when the signal strength drops below the minimum
threshold setting. If set to
true
, the BelAir100SN drops the link.
Mobile Link Identifier
/services/mobility/set network-identifier <net_id>
This command let you configure a mobile link identifier, consisting of up to 20
characters.
Example
/services/mobility# set network-identifier mobilityTest
Home Check
/services/mobility/set home-check {enabled|disabled} <home_id>
This command let you configure and activate the home check feature which
forces a subscriber station to connect to specific base station links. When
home check is enabled, the subscriber station accepts only base station links
that advertise a mobile link identifier that is exactly the same as the subscriber
station’s home-check identifier.
The specified home-check identifier can of up to 20 characters.
Base Station
Out-of-service Check
/services/mobility/set bs-oos-timeout <time-out>
/services/mobility/set bs-oos-broadcast {enabled | disabled}
These commands apply to base stations only. They let you configure and
activate the behavior when the base station can no longer egress traffic to an
outside network. The <time-out> parameter is a timer in seconds. Values
range from 60 to 86400. The default value is 300 seconds.
These commands work in conjunction with the
set system-egress-point
command described in
“Setting the Network Egress Point” on page 51
:
• If the system egress point is set to
direct
, then the base station
out-of-service timer starts when the Ethernet link becomes unavailable. If
the timer expires and the Ethernet link is still unavailable, then the base
station is taken out of service by prepending
bsOutOfService
to the mobile
link identifier.
• If the system egress point is set to
indirect
with a gateway IP address, then
the base station pings the gateway IP address and starts the out-of-service
timer if it does not receive a reply. If the timer expires and the gateway still
does not reply, then the base station is taken out of service by prepending
bsOutOfService
to the mobile link identifier.