-49-
©
BEKA 2019 All rights reserved!
BA
L_
ZE
PT
O_1
01
9D
E_
EN.docx
Level prewarning
(permanent display)
o
The inserted cartridge becomes empty
►
Insert new cartridge and reset level prewarning (see
chapter
11.5 “
Level prewarning
”
)
Motor error
o
The motor or the control in the device is defective
►
Renew device
Overvoltage error
o
The supplied operating voltage is too high (> 30 V)
►
Lower operating voltage
Undervoltage error
o
The supplied operating voltage is too low (< 9 V)
►
Raise operating voltage
Temperature error
o
The device is operated outside the indicated temperature
range
►
Heat or cool the device
Overpressure error (program P2)
o
Program
P2
is active and the device receives a signal
because no sensor is connected or the connected sensor
is defective
►
Connect the sensor or check the connected sensor
and renew it if necessary
o
Program
P2
is active and the device receives a signal
because the pressure in the system has exceeded 290 bar
and the pressure limiting valve has opened
►
Check system for blockades and leakages and
eliminate them
Pulse error (program P3)
o
Program
P3
is active, but the device receives no pulse
signal because no sensor is connected or the connected
sensor is defective
►
Connect the sensor or check the connected sensor
and renew it if necessary
o
Program
P3
is active, but the device receives no pulse
signal because there is a blockade in the lubrication
system
►
Check system for blockades and leakages and
eliminate them
Содержание ZEPTO
Страница 27: ...27 BEKA 2019 Alle Rechte vorbehalten BAL_ZEPTO_1019DE_EN docx 18 Ma zeichnung...
Страница 52: ...BEKA 2019 All rights reserved 52 BAL_ZEPTO_1019DE_EN docx 18 Dimensional drawing...
Страница 53: ...53 BEKA 2019 BAL_ZEPTO_1019DE_EN docx Einbauerkl rung Declaration of incorporation...
Страница 54: ...BEKA 2019 54 BAL_ZEPTO_1019DE_EN docx...
Страница 55: ...55 BEKA 2019 BAL_ZEPTO_1019DE_EN docx...