11.6 Setting the cartridge size
The device must be set to the inserted cartridge size in order to enable a reliable use of the level prewarning:
Hold down the
left
control key and the
push-button for intermediate lubrication
until
“
C
”
appears in the left segment of
the display.
Press the push-button for intermediate
lubrication as often as required until the
desired setting is reached.
The
control
saves
the
setting
automatically; no further confirmation is
necessary.
Setting
Filling quantity
C0
350 g
C1
400 g (Standard)
C2
450 g
C3
500 g
C4
550 g
11.7 Operating hours counter
The device has an integrated operating hours counter which indicates the operating time of the device in emptied cartridges (400g).
Hold down the push-button for intermediate
lubrication until
“
CC
”
appears.
Release push-button for
intermediate lubrication
and wait until display
changes
The number of emptied cartridges is displayed
* see also chapter
10.2.1 “Display sequence of the push
-
button for intermediate lubrication”
Display and evaluation
10** cartridges
10** +
1
x 100 =
110 cartridges
10** +
2
x 100 =
210 cartridges*
10** +
3
x 100 =
310 cartridges*
10** +
4
x 100 =
410 cartridges
** Example
Содержание ZEPTO
Страница 27: ...27 BEKA 2019 Alle Rechte vorbehalten BAL_ZEPTO_1019DE_EN docx 18 Ma zeichnung...
Страница 52: ...BEKA 2019 All rights reserved 52 BAL_ZEPTO_1019DE_EN docx 18 Dimensional drawing...
Страница 53: ...53 BEKA 2019 BAL_ZEPTO_1019DE_EN docx Einbauerkl rung Declaration of incorporation...
Страница 54: ...BEKA 2019 54 BAL_ZEPTO_1019DE_EN docx...
Страница 55: ...55 BEKA 2019 BAL_ZEPTO_1019DE_EN docx...