-29-
10 - Capacity check / LED messages
The remaining capacity of the
BEKAONE120
is indicated on the LED display after each normal
lubrication cycle (see graphic and table). To check the remaining capacity explicitly, activate an
intermediate lubrication.
Filling
cycles
3
> 600 cm
3
3
600 cm - 481 cm
3
3
480 cm - 361 cm
3
3
360 cm - 241 cm
3
3
240 cm - 121 cm
3
< 120 cm
> 2500
2500 - 2001
2000 - 1501
1500 - 1001
1000 - 501
< 500
Example: 5 filling cycles
(>4 remaining reservoir
discharges)
6
4
5
3
2
1
LED
Status
Cause
Troubleshooting
green
red
ON
Flashes every 60 s
Device is currently lubricating
Function control (=ok), device is activated
Flashes 2x shortly
every 10 s
Flashes every 10 s
Backpressure
is too high
Max. number of cycles
is reached
Low battery
Unscrew the device, switch it off and on:
- Pump is running
→
check the lube point for too high backpressure
→
correct error
→
screw the device in again
- Device does not work
→
replace the device
Replace the device
Remaining
capacity
Remaining
reservoir discharges
(complete reservoir)
Possible
lubrication pulses
(cycles)
LED messages
EN
Содержание ONE 120
Страница 3: ...Montageanleitung und Hinweise zum Betrieb DE ...
Страница 17: ... 16 Assembly and operating instructions EN ...
Страница 31: ... 30 Manual de montaje e instrucciones de uso ES ...
Страница 45: ... 44 Manual de montagem e instruções de uso PT ...
Страница 59: ... 58 安装与操作说明 漢語 ...
Страница 73: ...Declaration of conformity and incorporation 72 ...
Страница 74: ... 73 Declaration of conformity and incorporation ...
Страница 75: ...Declaration of conformity and incorporation 74 ...
Страница 76: ......