![BEKA BEKA-MAX OC-1 Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/beka/beka-max-oc-1/beka-max-oc-1_manual_2723978008.webp)
8
Integrated electronic controlling device BEKA-troniX1:
Whatever program is being used, once the ignition has
been switched on the green and the red LED or the green
and the red signal lamp (optional) lights up on the control
panel for 1 5 sec. and shows that the controller is
.
operational (activation control).
Every time the controller is activated for the first time, a
lubrication process begins. The green LED in the control
half shell is lit during the entire lubrication procedure.
The BEKA-troniX1 integrated electronic controlling device
has memory at its disposal. This also serves to keep a
record of time elapsed. Should the ignition be switched off
during lubrication or operational pauses occur, then the
time is stopped and recorded. Once the ignition is switched
on again the remaining lubrication or pause time is read
from the memory and the sequence will be resumed where
it was interrupted.
At any time when the ignition is on, an interim lubrication
occurs when the button on the side of the pump motor
housing or the illuminated button on the control panel is
activated, this serves as a check of functionality. The pump
then immediately starts its lubrication cycle, the lubrication
or cycle duration recorded up to that point is reset and starts
from the beginning.
An interim lubrication can also be triggered via an external
button, and the indication of the red and green LEDs can
also be displayed by a red and green signal lamp in the
driver´s cab.
A error can be reset by pressing the interim lubrication
button and the pump starts the lubrication process anew.
The lamp on the illuminated button (green) shows the
functionality of the controller and the current lubrication
sequence.
Multi line pump OC-1
Function of BEKA-troniX1
Subject to alterations!
Button for
triggering
an intermediate
lubrication
Green LED to show function
Red LED to show malfunctions
16
1
Cycle time (h)
Service
EA / PA Controller
Typ BEKA-troniX1
Lubrication time (min.)
8
0,5
8
0,5
...een product van BEKA