![BEKA BEKA-MAX OC-1 Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/beka/beka-max-oc-1/beka-max-oc-1_manual_2723978011.webp)
11
Multi line pump OC-1
Summary of signal indicators of BEKA-troniX1
The pump´s functions are indicated via two control LEDs
(green/red) in the display on the pump´s motor casing,
where the red LED always indicates an error in the program
sequence.
These control LED functions may be indicated in the
driver´s cap of the vehicle via built-in signal lamps. These
must be specially ordered.
a)
Standby
b)
Lubrication activated
c)
Grease level error
d)
Speed error
e)
Memory error
f)
Test lubrication (constant lubrication)
To adjust the time controlling to continual lubrication for
servicing purposes, the lubrication time must be set
a
to
higher value than the cycle duration.
BEKA-troniX1 integrated electronic controller:
Subject to alterations!
Standby: 1,5 sec.
ON
OFF
OFF
ON
LED red
LED green
Standby indicator:
LED green
During whole lubrication
ON
OFF
OFF
ON
LED red
Lubrication sequence:
16
1
Cycle time (h)
Service
EA / PA Controller
Typ BEKA-troniX1
Lubrication time (min.)
8
0,5
8
0,5
Red LED error indicator
Green LED function indicator
LED red
Until the reservoir is filled
ON
OFF
ON
OFF
LED green
Grease level too low:
LED red
1 sec.
1 sec.
OFF
ON
ON
OFF
LED green
Speed error at pump element:
LED red
0,5 sec.
0,5 sec.
ON
OFF
ON
OFF
LED green
Memory error:
LED green
LED red
1 sec.
1 sec.
ON
OFF
ON
OFF
Test lubrication:
...een product van BEKA