24
Display
Summary of function
uP or dn
Direction of count
Defines whether the Timer
times-down
from
5Et t'
to zero or
times-up
from
zero to the set time
5Et t
.
See section 6.5.16
P-FAiL
Power Failure
Defines how the Timer functions when
power is restored after a power failure.
Contains three sub-functions
idle
,
Pau5E
and
continue
.
idle
Timer returns in stopped state
as if having completed a
single timing cycle displaying
Timer value when power was
lost. Timing resumes when
reset followed by start
instructions are received.
Pau5e
Timer returns in paused state
displaying Timer value when
power was lost. Timing
resumes
when
start
instruction is received.
Continue
Timer will continue without
any manual intervention.
See section 6.5.17
LoC r5Et
Local reset
Contains two sub-functions which when
enabled allow the Timer and the grand
total, which represents total Timer run-
time, to be reset to zero via the front
panel push buttons while the Timer is in
the display mode.
See section 6.5.18
Local total reset
r5Et
.
EnbL
When
on
is selected, Timer is reset to
zero, or
5et t
if
timing-down
, when the
&
and
*
buttons are operated
simultaneously for more than 3
seconds in the display mode.
See section 6.5.19
Local grand total reset
CLr Gtot
When
on
is selected the grand total,
which represents total run-time, may be
reset to zero by operating the
)
+
*
buttons simultaneously for more
than 10 seconds in the display mode.
Note:
Once reset, the grand total can
not be recovered.
See section 6.5.20
Display
Summary of function
oP1
Control output 1 (Optional)
Contains sub-menu with four sub-
functions,
EnbL
,
oP1 on
,
oP1 oFF
and
oP1 dELA
.
See section 6.5.21
Control output enable
EnbL
Enables or disables control output 1
without changing the parameters.
See section 6.5.22
Control output 1 on at
oP1 on
Defines when the control output turns
on (closes).
See section 6.5.23
Control output 1 off at
oP1 oFF
Defines when the control output turns
off (opens).
See section 6.5.24
Control output 1 delay
oP1 dELA
Introduces a configurable delay
between the
oP1 on
condition occurring
and the control output turning on
(closing).
See section 6.5.25
oP2
Control output 2 (Optional)
Functions as control output 1.
See section 6.5.26
Содержание BA377E
Страница 1: ...Issue 6 4th May 2021 BA377E Single input Intrinsically safe Timer or Clock Issue 6...
Страница 28: ...28...
Страница 29: ...29...
Страница 40: ...40...
Страница 51: ...51...
Страница 52: ...52...
Страница 53: ...53...
Страница 54: ...54...
Страница 55: ...55...
Страница 56: ...56...
Страница 57: ...57...
Страница 58: ...58...
Страница 59: ...59...
Страница 60: ...60...
Страница 61: ...61...
Страница 62: ...62...