13
5.
ACCESSORIES
5.1
Display backlight
The BA374NG Timer or Clock can be supplied with
a factory fitted backlight that produces green
illumination enhancing display contrast and enabling
it to be read at night or in poor lighting conditions.
The backlight is internally powered from the
instrument power supply so no additional wiring is
required, but the supply current increases as shown
below.
BA374NG
configured as Timer
current
consumption
BA374NG Timer or Clock
10mA
Additional for backlight
16mA
Addition with terminals 3 & 4 linked
6mA
Addition with terminals 7 & 8 linked
6mA
---------------
Total current
38mA max
BA374NG
configured as Clock
current
consumption
BA374NG Timer or Clock
10mA
Additional for backlight
16mA
---------------
Total current
26mA max
5.2
Control outputs
Although the dual isolated control outputs are factory
fitted options, they are described in the main body of
this instruction manual as they will be used for the
majority of applications. If control outputs are
required they should be specified when the
instrument is ordered.
5.3
Units of measurement & instrument
identification.
New BA374NG Timer or Clocks are supplied with a
printed scale card showing the units of
measurement and tag information specified when
the instrument was ordered. If this information was
not supplied a blank scale card will be fitted which
can easily be marked with a dry transfer or a
permanent marker on-site.
Custom printed scale cards are available as
accessories and may be easily fitted as shown in
section 4.4 of this manual.
5.4 Legend plate
The BA374NG can also be supplied with a blank or
custom laser engraved stainless steel legend plate -
see Fig 8. The plate, which after installation is
visible from the front of the instrument, is supplied
loose with two fixing screws for securing it to the
rear of the instrument's back-box. This plate can
typically accommodate:
1 row of 5 alphanumeric characters 10mm high
or 1 row of 6 alphanumeric characters 7mm high
or 2 rows of 10 alphanumeric characters 5mm high
5.5 BA393G pipe mounting kit
316 stainless steel pipe mounting kit, attaches a
BA374NG to any vertical or horizontal pipe with an
outside diameter between 40 and 73mm.
5.6 BA394G panel mounting kit
The BA374NG may be panel mounted using a
BA394G stainless steel panel mounting kit. This
secures the BA374NG into a panel aperture and
maintains the ingress protection of the instrument,
but it does not provides an IP66 seal between the
front and rear of the panel in which the BA374NG
Timer or clock is mounted.