48
Step 6 Enable control output 2 and enter the
on
and
off
times.
Using the
*
or
&
button select
oP2
in the
configuration menu and press
(
to reveal
the
EnbL
prompt in the control output 2 sub-
menu. Follow the procedure described in
step 5 above, but set control output 2 to turn
on
at
18
:
00
:
00
and
off
at
22
:
30
:
00
.
Step 7 Allow control outputs times to be
adjusted from the display mode & enter
separate security code.
Using the
*
or
&
button select
AC5P
in the
configuration menu and press
(
to reveal
the
EnbL
prompt, pressing
(
again will
show if this function is
on
or
oFF
.
Using the
*
or
&
button select
on
followed by
)
to
return to the
EnbL
prompt. A separate
security code which must be entered to gain
access to the alarm times in the display
mode, is entered in the
ACCd
function which
may be selected by operating the
*
or
&
button once. Pressing
)
will reveal the
existing access code with one digit flashing.
This should be changed to the required
code of
1111
by adjusting the flashing digit
using using the
*
or
&
button and the
(
button to transfer control to the next digit.
When
1111
has been entered press
)
twice to return to the configuration menu.
See 9.4.16
Step 8 Define the configuration menu security
code.
Defining a security code prevents
unauthorised access to the configuration
menu. Using the
&
and
*
buttons select
CodE
from the configuration menu and press
(
which will reveal
0000
with the first digit
flashing. This example requires the security
code to be
1209
, using the
&
and
*
buttons set the flashing digit to
1
and press
(
to transfer control to the second digit.
When all have been entered press
)
to
return to the main configuration menu.
See 9.4.17.
Step 9 Return to the display mode
The BA374NG is now configured as
required for this example. Pressing the
)
button will save the configuration and return
the BA374NG to the display mode with all
the digits flashing indicating that the set time
has to be entered.
Step 10 Enter the set time
Finally the current time to be displayed by
the Clock should be entered. Re-enter the
configuration menu by pressing the
(
and
)
buttons simultaneously which will result
in
code
being displayed. Pressing
(
will
allow the access code
1209
to be entered
using the
&
or
*
button to adjust the
flashing digit and the
(
button to transfer
control to the next digit. When all four digits
have been adjusted, press
(
to enter the
configuration menu and using the
&
or
*
button select
5Et
and press
)
which will
reveal
00
:
00
:
00
with the hours flashing.
Using the
&
or
*
button adjust the
flashing hours digit and press
(
to transfer
control to the minutes and then to the
seconds. When all have been set as
required, press
)
to start the clock from
the entered time and return to the display
mode.
Содержание BA374NG