Step 12 Turn local clear off
In this example the operator must not be
able to zero the total (cable position)
display or the grand total from the
instrument front panel. Both local clear
functions should therefore be turned off.
Select
LoC CLr
from the main menu and
press
(
which will result in
Clr tot
being displayed, press
(
again to show
if the function is turned
on
or
oFF
. Using
the
&
or
*
button toggle the display to
oFF
and press
)
to return to the
Clr tot
prompt from which
Clr Gtot
can be
selected by pressing the
&
or
*
button.
Turn this function off in exactly
the same way before returning to the
configuration menu by pressing the
)
button twice.
Step 13 Define the security code
Defining
an
access
security
code
prevents unauthorised access to the
configuration menu.
Select
CodE
in the
configuration menu and press
(
which
will reveal the existing security code with
the first digit flashing. Using the
&
and
*
buttons enter the new code 1209 digit
by digit. The
(
button transfers control
between digits. When the new code has
been entered, press
)
to return to the
configuration menu.
Step 14 Return to the display mode
Following completion of configuration,
return the BA364G to the display mode
by pressing
)
.
The instrument will
display
dAtA
followed by
5AVE
while the
configuration changes are stored in
permanent memory.
34
Содержание BA364E
Страница 1: ...Issue 5 9th July 2019 BA364G and BA364E Two Input Intrinsically safe Counter Issue 5 ...
Страница 20: ...20 ...
Страница 21: ...21 ...
Страница 47: ...47 ...
Страница 48: ...48 ...
Страница 49: ...49 ...
Страница 50: ...50 ...
Страница 51: ...51 ...
Страница 52: ...52 ...
Страница 53: ...53 ...
Страница 54: ...54 ...
Страница 55: ...55 ...
Страница 56: ...56 ...
Страница 57: ...57 ...
Страница 58: ...58 ...