9.3.10  Alarm delay:   dELA

This function enables activation of the alarm
output to be delayed for a fixed time
following the alarm condition occurring.  The
delay can be programmed in 1 second
increments up to 3600 seconds.  If a delay is
not required zero should be entered.  To
adjust the delay select 'dELA' from the alarm
menu and press P which will reveal the
existing delay.  Each digit of the delay can
be adjusted using the Up and Down push-
buttons, and the P  button to move to the
next digit.  When the required delay has
been entered, press E to return to the alarm
menu.
The alarm annunciator will start flashing
immediately an alarm occurs and continue
for the delay time after which the alarm
output will be activated.

9.3.11  Alarm silence time:   SIL

This function is primarily intended for use in
small installations where the alarm output
directly operates an annunciator such as a
sounder.  When the alarm silence time is set
to any figure other than zero, the P push-
button becomes an alarm accept button.
After an alarm has occurred, operating the P
button will cause the alarm output to revert
to the non-alarm condition for the
programmed alarm silence time.     The
silence time may be adjusted between 0 and
3600 seconds in 1 second increments.

To adjust the alarm silence time select 'SIL'
from the alarm menu and press P  which will
reveal the existing time.  Each digit can be
adjusted using the Up and Down push-
buttons, and the P  button to move to the
next digit.  When the required time has been
entered press E to return to the alarm menu.
When an alarm is silenced the alarm
annunciator will flash until the silence time
expires.

9.3.12  Access Setpoint:  AcSP

This function controls a separate menu
which provides direct access to the alarm
setpoints when the instrument is in the
operating mode.  See section 9.3.13 for a
full description.    An operator may therefore
adjust the alarm setpoints without having
access to the programme and alarm menus.
Further protection is provided by a separate
security code.

This direct access menu is enabled and a
separate security code entered from the
'AcSP' function in the main programme
menu.  To change the menu parameters

select 'AcSP' from the programme menu and
press P which will display the enable prompt
'EnbL'.  Press P again to reveal if the direct
access menu is 'On' or 'OFF'.  The Up or
Down buttons will toggle the display
between the two conditions.

If 'OFF' is selected, the operator will not
have access to the setpoints from the
display mode.  Press E twice to return to the
‘AcSP’ prompt in the main menu.

If 'On' is selected, the operator will have
direct access to the alarm setpoints from the
display mode via a separate optional
security code.   To define the four digit
numerical code press E to return to the
'Enbl' prompt followed by the Up or Down
button to select the access code prompt
'AcCd'.   Pressing P will reveal the current
security code.  Each digit of the code may
be changed by operating the Up and Down
push-buttons, and the P button to move to
the next digit.  When the required code has
been entered, press E twice to return to the
'AcSP' prompt in the Programme Menu.

The default code 0000 will disable the
security code allowing direct access to the
setpoints by pressing the P and Up buttons
simultaneously.

New instruments with alarms are supplied
with this function disabled and the security
code set to 0000

9.3.13  Adjusting alarm setpoints from
           the display mode

Access to the two alarm setpoints from the
indicator display mode is obtained by
operating the P and Up push-buttons
simultaneously as shown in Fig 13.  If the
setpoints are not protected by a security
code the alarm setpoint prompt 'SPr1' or
'SPt1' will be displayed depending upon
whether a rate or total alarm has been
programmed.  If the setpoints are protected
by a security code, 'COde' will be displayed
first.  Pressing P again will enable the alarm
security code to be entered digit by digit
using the Up and Down buttons to change
the flashing digit, and the P push-button to
move to the next digit.  If the correct code is
entered pressing E will cause alarm setpoint
prompt 'SPr1' or 'SPt1' to be displayed.
Pressing the Up or Down button will then
toggle the display between the two alarm
setpoint prompts.

Содержание BA358C

Страница 1: ...October 2010 BA358C Intrinsically safe 4 20mA loop powered panel mounting rate totaliser Issue 4 Certification information label Rate display Annunciators for optional alarms Rotating flow indicator T...

Страница 2: ...1 Timebase 6 12 Function of the P push button 6 13 Total scale factor 6 14 Percentage clip off 6 15 Local reset of total display 6 16 Security code 6 17 Over and under range 7 Calibration Examples 7 1...

Страница 3: ...sed diode D1 The voltage developed across D1 which is relatively constant is multiplied by a switch mode power supply and used to power the instrument The voltage developed across R1 which is proporti...

Страница 4: ...eds 4mA 3 INTRINSIC SAFETY CERTIFICATION 3 1 ATEX certificate The BA358C has been issued with an EC Type Examination Certificate by Notified Body Intertek Testing Services ITS formerly ERA Technology...

Страница 5: ...Zones gas groups and T rating The BA358C has been certified to show compliance with the requirements for Group II Category 1G equipment EEx ia IIC T5 When connected to a suitable system the instrumen...

Страница 6: ...dication of rate and total flow within a hazardous area The type of interface is not critical either a Zener barrier or a galvanic isolator may be used providing that Uo Io and Po are not exceeded If...

Страница 7: ...esetting from the safe area via a single channel diode return Zener barrier A certified intrinsically safe relay or certified opto isolator may also be used Fig 3B shows how the total display may be r...

Страница 8: ...lective displays there is little degradation of contrast when viewed from above the centre line but slight degradation may be noticeable when the instrument is fitted with a backlight Fig 4 BA358C dim...

Страница 9: ...in the rate display is defined by the d p function To simplify calibration the BA358C uses floating point arithmetic moving the rate display decimal point position will therefore affect totalisation T...

Страница 10: ...of 0 00 with 4mA input and 100 00 with 20mA input The total scale factor will be set to 1 0000 with a timebase of flow per second The instrument can easily be recalibrated on site 6 3 Summary of progr...

Страница 11: ...input current in milliamps or the input as a percentage when the P push button is operated in the display mode Select PC for of span and 4 20 to display current See section 6 12 Display Description o...

Страница 12: ...cimal point clip off to adjust value Press or between 0 and 10 or and pressing Define Security Enter by Code to move to next digit Local reset or Fig 7B Programme Structure CLr Gtot E E E E E E E E P...

Страница 13: ...or and Similarly set the required full scale display accurate 20mA input current scale display using an Similarly set the required full to move to next digit pressing or and set required zero display...

Страница 14: ...s Operating the P push button will toggle control between the two displays When both decimal points have been correctly positioned press E to return to the main menu If the application requires flow r...

Страница 15: ...ay 0000 Using the Up and Down buttons and the P button to move to the next digit enter the password SurE S is entered as 5 Pressing E will then give access to the sub menu 6 9 1 AC rejection FrE WARNI...

Страница 16: ...our Tb 3600 3600 Select the required divisor and press E to return to the main menu 6 12 Function of the P push button C P This parameter defines the function of the P push button when the BA358C is i...

Страница 17: ...lect CLIP OFF from the main menu and press P to reveal the current setting This clip off threshold is shown as a percentage of total flow and may be adjusted in one percent increments using the Up or...

Страница 18: ...ction 7 1 describes the preferred method of calibration using an external traceable 4 20mA calibrator Section 7 2 contains an example of calibration using the BA358C internal 4 and 20mA references whi...

Страница 19: ...git of the total display flashing Press the Up or Down push button until the second least significant digit and following decimal point of the total display flash This gives the required total display...

Страница 20: ...to the main menu by pressing E Step 12 Reset the grand total to zero To reset the grand total to zero select CLr Gtot from the main menu and press P which will cause the instrument to display Clr no T...

Страница 21: ...multaneously pressing P and E Assuming a security code has not already been entered the instrument will respond by displaying root which is the first function in the main menu Steps Perform as describ...

Страница 22: ...terminals 1 3 No power supply Confirm that a 4 20mA current is flowing in the loop Unstable rate display 4 20mA current is noisy or the flow signal is unstable Eliminate source of electrical noise Red...

Страница 23: ...ons available for a rate alarm and shows which are fail safe i e output is in the alarm condition open when the 4 20mA input current is zero Similarly when programmed as a total alarm the output shoul...

Страница 24: ...nt capacitance and inductance of each BA358C alarm output is Ci 40nF Li 20 H The maximum permissible cable parameters for the alarm circuit will be the figures specified for the barrier or isolator le...

Страница 25: ...veal the current setting The function can be changed by pressing the Up or Down button followed by the E button to return to the alarm menu 9 3 5 Type of alarm tYPE This function conditions the alarm...

Страница 26: ...Down button followed by the E button to return to the alarm menu 9 3 9 Hysteresis HStr Hysteresis is only available on rate alarms During programming hysteresis is shown in the units of rate the BA358...

Страница 27: ...This direct access menu is enabled and a separate security code entered from the AcSP function in the main programme menu To change the menu parameters select AcSP from the programme menu and press P...

Страница 28: ...is segregated from the measuring circuit and has been certified as a separate intrinsically safe circuit but it does not comply with the requirements for simple apparatus Systems certificates for use...

Страница 29: ...ere the instrument is likely to be damaged by impact an additional front cover is available The BA398 is a robust transparent cover which is secured to the panel by six screws and sealed with a neopre...

Страница 30: ...missioning 8 1 after commissioning 8 2 Flow indicator 2 2 Flow transmitter loops 4 1 Galvanic isolators 4 0 Gas groups 3 4 Grand total 2 1 clear 6 3 6 10 Guarantee 8 5 HI LO 9 3 3 9 3 7 HStr 9 3 3 9 3...

Отзывы: